Calibration of the Rossi X-ray timing explorer proportional counter array

K Jahoda, CB Markwardt, Y Radeva… - The Astrophysical …, 2006 - iopscience.iop.org
We present the calibration and background model for the Proportional Counter Array on
board the Rossi X-Ray Timing Explorer. The energy calibration is systematics-limited below …

In-orbit performance and calibration of the Rossi X-ray Timing Explorer (RXTE) Proportional Counter Array (PCA)

K Jahoda, JH Swank, AB Giles… - Euv, x-ray, and …, 1996 - spiedigitallibrary.org
The proportional counter array (PCA) is designed to perform microsecond timing of bright
galactic sources and broad band, confusion limited, studies of faint extragalactic sources in …

Mean energy required to produce an electron-hole pair in silicon for photons of energies between 50 and 1500 eV

F Scholze, H Rabus, G Ulm - Journal of Applied Physics, 1998 - pubs.aip.org
The photon energy dependence of the mean energy W required to produce an electron-hole
pair in silicon for photons with energies between 50 and 1500 eV was determined from the …

Full-energy absorption of x-ray energies near the Xe - and -photoionization thresholds in xenon gas detectors: Simulation and experimental results

T Dias, JMF Dos Santos, P Rachinhas… - Journal of applied …, 1997 - pubs.aip.org
Distributions of the number of primary electrons produced per incident mono-energetic x-
rays in the 1-to 41-keV energy range, which includes the xenon L-and K-absorption edges …

Experimental Study of the -Values and Fano Factors of Gaseous Xenon and Ar-Xe Mixtures for X-Rays

SJC Do Carmo, FIGM Borges… - … on Nuclear Science, 2008 - ieeexplore.ieee.org
An experimental study of the w-values and Fano factors for Ar-Xe gaseous mixtures at
atmospheric pressures for 5.895 keV X-rays was carried out with two experimental set-ups …

4.2 Gas Proportional Scintillation Counters for X-ray Spectrometry

CAN Conde - X-ray spectrometry: recent technological …, 2004 - Wiley Online Library
X-Ray spectrometry is usually performed with one of two techniques: energy dispersive and
wavelength dispersive. Energy dispersive techniques use radiation detectors that give a …

Energy linearity of high-purity germanium detectors in the region of the Ge K-absorption edge: experimental results

JMF Dos Santos, CMB Monteiro, RE Morgado… - Applied Radiation and …, 2000 - Elsevier
Non-linearities in the energy response of gas detectors in the regions of the absorption
edges of the detection medium are well documented. Monte Carlo calculations show that the …

A new technique for studying the Fano factor and the mean energy per ion pair in counting gases

A Pansky, A Breskin, R Chechik - Journal of applied physics, 1996 - pubs.aip.org
A new method is presented for deriving the Fano factor, F, and the mean energy per ion pair,
W i, in counting gases. It is based on the technique of individual counting of single ionization …

The response of xenon X-ray detectors to full-energy absorption and fluorescence-escape events: measurement and modelling

T Dias, FP Santos, JMF Dos Santos… - … on Nuclear Science, 1996 - ieeexplore.ieee.org
We have observed that the pulse-height distributions of X-ray events that deposit essentially
the same amount of energy in a xenon gas detector will vary according to the deexcitation …

Linearity discontinuities in Xe-filled X-ray microstrip detectors

G Zavattini, M Feroci, C Budtz-Jørgensen… - Nuclear Instruments and …, 1997 - Elsevier
A prototype Xe÷ 10% CH4 microstrip detector was used to study the K-edge discontinuity in
the pulse-height distribution as a function of the energy of incident X-rays. The electronics …