Experimental tests of particle flow calorimetry

F Sefkow, A White, K Kawagoe, R Pöschl… - Reviews of Modern Physics, 2016 - APS
Precision physics at future colliders requires highly granular calorimeters to support the
particle flow approach for event reconstruction. This article presents a review of about 10–15 …

A highly granular SiPM-on-tile calorimeter prototype

F Sefkow, F Simon… - Journal of Physics …, 2019 - iopscience.iop.org
Abstract The Analogue Hadron Calorimeter (AHCAL) developed by the CALICE
collaboration is a scalable engineering prototype for a Linear Collider detector. It is a …

MINERvA neutrino detector response measured with test beam data

L Aliaga, O Altinok, CA Del Castillo, L Bagby… - Nuclear Instruments and …, 2015 - Elsevier
The MINERvA collaboration operated a scaled-down replica of thesolid scintillator tracking
and sampling calorimeter regions of the MINERvA detector in a hadron test beam at the …

[图书][B] Plastic scintillators

M Hamel - 2021 - Springer
Cross-disciplinary research is extremely pleasant to open-minded scientists who love to exit
from their comfort background, and learn new subjects. The scintillation domain—and more …

Design, construction and commissioning of a technological prototype of a highly granular SiPM-on-tile scintillator-steel hadronic calorimeter

A White, J Yu, G Eigen, J Zalieckas… - Journal of …, 2023 - iopscience.iop.org
The CALICE collaboration is developing highly granular electromagnetic and hadronic
calorimeters for detectors at future energy frontier electron-positron colliders. After …

A high-granularity calorimeter insert based on SiPM-on-tile technology at the future Electron-Ion Collider

M Arratia, K Barish, L Blanchard, HZ Huang, Z Ji… - Nuclear Instruments and …, 2023 - Elsevier
We present a design for a high-granularity calorimeter insert for future experiments at the
Electron-Ion Collider (EIC). The sampling-calorimeter design uses scintillator tiles read out …

[HTML][HTML] Testing hadronic interaction models using a highly granular silicon–tungsten calorimeter

B Bilki, J Repond, J Schlereth, L Xia, Z Deng… - Nuclear Instruments and …, 2015 - Elsevier
A detailed study of hadronic interactions is presented using data recorded with the highly
granular CALICE silicon–tungsten electromagnetic calorimeter. Approximately 350,000 …

The time structure of hadronic showers in highly granular calorimeters with tungsten and steel absorbers

C Adloff, JJ Blaising, M Chefdeville… - Journal of …, 2014 - iopscience.iop.org
The intrinsic time structure of hadronic showers influences the timing capability and the
required integration time of hadronic calorimeters in particle physics experiments, and …

Shower development of particles with momenta from 15 GeV to 150 GeV in the CALICE scintillator-tungsten hadronic calorimeter

M Chefdeville, Y Karyotakis, J Repond… - Journal of …, 2015 - iopscience.iop.org
We present a study of showers initiated by electrons, pions, kaons, and protons with
momenta from 15 GeV to 150 GeV in the highly granular CALICE scintillator-tungsten …

[HTML][HTML] Optimising longitudinal and lateral calorimeter granularity for software compensation in hadronic showers using deep neural networks

C Neubüser, J Kieseler, P Lujan - The European Physical Journal C, 2022 - Springer
We investigate the effect of longitudinal and transverse calorimeter segmentation on event-
by-event software compensation for hadronic showers. To factorize out sampling and …