[HTML][HTML] Hybrid Garfield++ simulations of GEM detectors for tokamak plasma radiation monitoring

M Jagielski, K Malinowski, M Chernyshova - Fusion Engineering and …, 2023 - Elsevier
This work presents recent efforts in optimization of Gas Electron Multiplier (GEM) detector
simulations developed so far. The mentioned triple-GEM based measurement systems were …

Development of 2D GEM-based SXR plasma imaging for DTT device: focus on readout structure

M Chernyshova, K Malinowski, S Jabłoński… - Fusion Engineering and …, 2021 - Elsevier
Creation and development of a new diagnostics useful for future thermonuclear reactors and
helpful in studying impurity profiles, MHD modes/localization, and imaging are among …

Advantages of Al based GEM detector aimed at plasma soft− semi hard X-ray radiation imaging

M Chernyshova, K Malinowski, T Czarski… - Fusion Engineering and …, 2019 - Elsevier
Abstract Development of gaseous detectors, more specifically Gas Electron Multiplier (GEM)
based detectors, for application at tokamak plasma radiation monitoring/imaging in Soft …

Design and characterization of a new high-count wide-range fission chamber based on GEM

YX Ye, XL Zhao, XD Wang, S Feng, Q Wei… - Journal of …, 2024 - iopscience.iop.org
As one of the main detectors for monitoring neutron flux rate in a nuclear reactor, the fission
chamber (FC) suffers from issues such as low sensitivity, limited counting rate dynamic …

Study on silicon drift detector efficiency using Monte–Carlo simulation and experimental methods

S Guo, J Wu, J Zhang, Z Fan, W Che… - The Journal of …, 2019 - Wiley Online Library
The energy calibration and efficiency calibration of one silicon drift detector (SDD) are
introduced here. The energy calibration is achieved using four radioactive sources, and the …

Thin film thickness measurement with triple gas electron multiplier detector by 55Fe radiation transmission and background detection using energy distribution …

F Fuentes, RM Gutiérrez - Instrumentation Science & Technology, 2020 - Taylor & Francis
The quality control of thin film thickness measurements through the transmission and
counting of beta and X-ray radiation has achieved very competitive precision with values to …

Energy calibration and performance testing of LEGe detector

D Hou, C Wu, C Li, S Guo, J Wu - The Journal of Engineering, 2019 - Wiley Online Library
The low energy germanium detector (LEGe) is in all aspects optimised for performance at
low and moderate energies. It has specific advantages over conventional planar or coaxial …

Simulations of X-ray conversion into primary electrons in GEM-based detector

K Malinowski, M Chernyshova, T Czarski… - Journal of …, 2020 - iopscience.iop.org
The paper presents the results of simulations of the interaction of X-rays of different discrete
energies (1–25 keV) with the structure of the GEM chamber. The simulations were …

Design and development of soft x-ray diagnostics based on GEM detectors at IPPLM

M Chernyshova, T Czarski… - … , Industry, and High …, 2019 - spiedigitallibrary.org
The search for new technologies in the field of plasma diagnostics entails the increasing
demands on the radiative stability of the used materials due to development and usage of …

Estudio computacional de un detector GEM para la producción de imágenes de rayos X

CA Barreto Neira - 2021 - repositorio.uniandes.edu.co
Resumen en español En este trabajo se realizó un estudio computacional de un detector de
radiación GEM con el objetivo de evaluar su desempeño para la obtención de imágenes de …