PHENIX calorimeter

L Aphecetche, TC Awes, J Banning, S Bathe… - Nuclear Instruments and …, 2003 - Elsevier
The PHENIX Electromagnetic Calorimeter (EMCal) is used to measure the spatial position
and energy of electrons and photons produced in heavy ion collisions. It covers the full …

PHENIX inner detectors

M Allen, MJ Bennett, M Bobrek, JB Boissevain… - Nuclear Instruments and …, 2003 - Elsevier
The timing, location and particle multiplicity of a PHENIX collision are determined by the
Beam–Beam Counters (BBC), the Multiplicity/Vertex Detector (MVD) and the Zero-Degree …

PHENIX muon arms

H Akikawa, A Al-Jamel, JB Archuleta… - Nuclear Instruments and …, 2003 - Elsevier
The PHENIX Muon Arms detect muons at rapidities of| y|=(1.2–2.4) with full azimuthal
acceptance. Each muon arm must track and identify muons and provide good rejection of …

Front-end electronics for multichannel semiconductor detector systems

P Grybos - 2010 - cds.cern.ch
Front-end electronics for multichannel semiconductor detektor systems Volume 08, EuCARD
Editorial Series on Accelerator Science and Technology The monograph is devoted to many …

PHENIX on-line systems

SS Adler, M Allen, G Alley, R Amirikas, Y Arai… - Nuclear Instruments and …, 2003 - Elsevier
The PHENIX On-Line system takes signals from the Front End Modules (FEM) on each
detector subsystem for the purpose of generating events for physics analysis. Processing of …

A low power multi-channel single ramp ADC with up to 3.2 GHz virtual clock

E Delagnes, D Breton, F Lugiez… - IEEE Transactions on …, 2007 - ieeexplore.ieee.org
During the last decade, ADCs using single ramp architecture have been widely used in
integrated circuits dedicated to nuclear science applications. These types of converters are …

Time-based analog to digital converters

S Naraghi - 2009 - search.proquest.com
Low-power, small analog-to-digital converters (ADCs) have numerous applications in areas
ranging from power-aware wireless sensing nodes for environmental monitoring to …

System for digitizing transient signals with waveform accumulator

MJ Pavicic - US Patent 6,975,251, 2005 - Google Patents
An apparatus for capturing and digitizing a signal derived from an event has a memory for
Storing a Sequence of analog Samples from the Signal derived from the event in a Sampling …

Design and characteristics of an integrated multichannel ramp ADC using digital DLL techniques for small animal PET imaging

W Gao, D Gao, C Hu-Guo, T Wei… - IEEE transactions on …, 2011 - ieeexplore.ieee.org
This paper presents a novel design of an integrated 12-bit multi-channel single-slope ramp
analog-to-digital converter (ADC) for a small animal positron emission tomography (PET) …

A complete read-out channel with embedded Wilkinson A/D converter for X-ray spectrometry

A Rossini, S Caccia, G Bertuccio… - … on Nuclear Science, 2007 - ieeexplore.ieee.org
This paper presents a complete read-out channel suitable for large arrays of X-ray detectors
to be used for spectrometry applications in space. The system is fully integrated except for …