S Cui, M Cohen, P Stabat, D Marchio - Building and environment, 2015 - Elsevier
The measure of air change rate (ACR) in building is a difficult and usually expensive task. The tracer gas method is the reference technique but its implementation is difficult and the …
The specific objectives of this work are to assess a Computational Fluid Dynamics (CFD) modelling performance through data of one experimental campaign, to quantify the impact of …
W Che, J Ding, L Li - Sustainable Cities and Society, 2022 - Elsevier
Abstract Since the Corona Virus Disease 2019 (COVID-19) outbreak, the normalization of the epidemic has posed great challenge to epidemic prevention and control in indoor …
HL Gough, Z Luo, CH Halios, MF King… - Building and …, 2018 - Elsevier
Currently, no clear standards exist for determining urban building natural ventilation rates, especially under varying realistic meteorological conditions. In this study, ventilation rates …
Turbulence dominates the natural ventilation of a building when openings are parallel to the external wind, and multiple factors associated with turbulence simultaneously affect natural …
CR Chu, YH Chiu, YT Tsai, SL Wu - Energy and Buildings, 2015 - Elsevier
This study uses wind tunnel experiments to investigate the wind-driven ventilation for buildings with two openings on a single wall. The exchange rates are measured by the …
In this study, field measurements of the natural ventilation rate of an experimental house with a symmetrical plan and two openings in the east-west direction were conducted under …
D Prakash, P Ravikumar - International Journal of Sustainable Built …, 2015 - Elsevier
Thermal comfort is an imperative factor that determines the health and productivity of the occupants living in residential buildings. The growing health related symptoms and demand …
Corner rooms with two or more open windows in perpendicular facades can be naturally ventilated in cross-ventilation or pumping ventilation. These two airflow regimes also occur …