Preschool multiple-breath washout testing. An official American Thoracic Society technical statement

PD Robinson, P Latzin, KA Ramsey… - American journal of …, 2018 - atsjournals.org
Background: Obstructive airway disease is nonuniformly distributed throughout the bronchial
tree, although the extent to which this occurs can vary among conditions. The multiple …

Inert gas washout: background and application in various lung diseases

J Usemann, S Yammine, F Singer, P Latzin - Swiss medical weekly, 2017 - zora.uzh.ch
Multiple breath inert gas washout (MBW) is a lung function technique to measure ventilation
inhomogeneity. The technique was developed more than 60 years ago, but not much used …

[HTML][HTML] Agreement between multiple-breath nitrogen washout systems in children and adults

W Poncin, F Singer, AS Aubriot, P Lebecque - Journal of cystic fibrosis, 2017 - Elsevier
Background Comparability of multiple breath washout (MBW) systems has been little
explored. We assessed agreement in lung clearance index (LCI) from two similar …

Particles in exhaled air (PExA): non-invasive phenotyping of small airways disease in adult asthma

M Soares, E Mirgorodskaya, H Koca… - Journal of breath …, 2018 - iopscience.iop.org
Rationale: Asthma is often characterised by inflammation, damage and dysfunction of the
small airways, but no standardised biomarkers are available. Objectives: Using a novel …

False normal lung clearance index in infants with cystic fibrosis due to software algorithms

P Anagnostopoulou, S Yammine… - Pediatric …, 2015 - Wiley Online Library
Background Lung clearance index (LCI), a marker of ventilation inhomogeneity, is elevated
early in children with cystic fibrosis (CF). However, in infants with CF, LCI values are found to …

Developments in multiple breath washout testing in children with cystic fibrosis

C Saunders, K Bayfield, S Irving, C Short… - Current Medical …, 2017 - Taylor & Francis
Background: Lung clearance index (LCI) is becoming recognized as an important addition in
the monitoring of pediatric cystic fibrosis (CF). The non-invasive technique is easy to perform …

Impact of software settings on multiple-breath washout outcomes

S Summermatter, F Singer, P Latzin, S Yammine - PloS one, 2015 - journals.plos.org
Background and Objectives Multiple-breath washout (MBW) is an attractive test to assess
ventilation inhomogeneity, a marker of peripheral lung disease. Standardization of MBW is …

In vitro and in vivo functional residual capacity comparisons between multiple-breath nitrogen washout devices

KO Tonga, PD Robinson, CS Farah, GG King… - ERJ open …, 2017 - Eur Respiratory Soc
Functional residual capacity (FRC) accuracy is essential for deriving multiple-breath
nitrogen washout (MBNW) indices, and is the basis for device validation. Few studies have …

Enhanced photoacoustic gas analyser response time and impact on accuracy at fast ventilation rates during multiple breath washout

A Horsley, K Macleod, R Gupta, N Goddard, N Bell - PLoS One, 2014 - journals.plos.org
Background The Innocor device contains a highly sensitive photoacoustic gas analyser that
has been used to perform multiple breath washout (MBW) measurements using very low …

Feasibility and clinical applications of multiple breath wash-out (MBW) testing using sulphur hexafluoride in adults with bronchial asthma

F Trinkmann, SA Lenz, J Schäfer, J Gawlitza… - Scientific reports, 2020 - nature.com
Ventilation heterogeneity is frequent in bronchial asthma and can be assessed using
multiple breath wash-out testing (MBW). Most data is available in paediatric patients and …