Initial clinical experience of Cherenkov imaging in external beam radiation therapy identifies opportunities to improve treatment delivery

LA Jarvis, RL Hachadorian, M Jermyn, P Bruza… - International Journal of …, 2021 - Elsevier
Purpose The value of Cherenkov imaging as an on-patient, real-time, treatment delivery
verification system was examined in a 64-patient cohort during routine radiation treatments …

Recent advances and clinical applications of plastic scintillators in the field of radiation therapy

S Beddar, I Tendler, F Therriault-Proulx… - Plastic Scintillators …, 2021 - Springer
Within the last three decades, a lot of interest focused on the development of plastic
scintillators as new detectors for clinical applications for radiation therapy. During the period …

[HTML][HTML] Experimentally observed Cherenkov light generation in the eye during radiation therapy

II Tendler, A Hartford, M Jermyn, E LaRochelle… - International Journal of …, 2020 - Elsevier
Purpose Patients have reported sensations of seeing light flashes during radiation therapy,
even with their eyes closed. These observations have been attributed to either direct …

Spatial and temporal dosimetry of individual electron FLASH beam pulses using radioluminescence imaging

M Rahman, MR Ashraf, R Zhang… - Physics in Medicine …, 2021 - iopscience.iop.org
Purpose. In this study, spatio-temporal beam profiling for electron ultra-high dose rate
(UHDR;> 40 Gy s− 1) radiation via Cherenkov emission and radioluminescence imaging …

Review of Cherenkov imaging technology advances in radiotherapy: single-photon-level imaging in high ambient light and radiation backgrounds

A Parks, J Hallett, A Niver, R Zhang… - Biophotonics …, 2024 - spiedigitallibrary.org
Significance Single-photon-level imaging has been utilized for decades in closed dark
environments; however, the utility for macroscopic imaging is more limited because it …

Assessment of imaging Cherenkov and scintillation signals in head and neck radiotherapy

DA Alexander, II Tendler, P Bruza, X Cao… - Physics in Medicine …, 2019 - iopscience.iop.org
The goal of this study was to test the utility of time-gated optical imaging of head and neck
(HN) radiotherapy treatments to measure surface dosimetry in real-time and inform possible …

[HTML][HTML] Rapid multisite remote surface dosimetry for total skin electron therapy: scintillator target imaging

I Tendler, P Brůža, J Andreozzi, M Jermyn… - International Journal of …, 2019 - Elsevier
Purpose The goal of this work is to produce a surface-dosimetry method capable of
accurately and remotely measuring skin dose for patients undergoing total skin electron …

Characterization of a non-contact imaging scintillator-based dosimetry system for total skin electron therapy

II Tendler, P Bruza, M Jermyn, X Cao… - Physics in Medicine …, 2019 - iopscience.iop.org
Surface dosimetry is required for ensuring effective administration of total skin electron
therapy (TSET); however, its use is often reduced due to the time consuming and complex …

Direct in-water radiation dose measurements using Cherenkov emission corrected signals from polarization imaging for a clinical radiotherapy application

É Cloutier, L Beaulieu, L Archambault - Scientific Reports, 2022 - nature.com
Cherenkov emission (CE) is a visible blueish light emitted in water mediums irradiated by
most radiotherapy treatment beams. However, CE is produced anisotropically which …

Improvements to an optical scintillator imaging-based tissue dosimetry system

II Tendler, P Bruza, M Jermyn, A Fleury… - Journal of …, 2019 - spiedigitallibrary.org
Previous work has shown that capturing optical emission from plastic discs attached directly
to the skin can be a viable means to accurately measure surface dose during total skin …