Continuous generation of electricity of a power plant depends on the higher availability of its components/equipments. Higher availability of the components/equipments is inherently …
Coal-fired boiler tubes are generally exposed to high internal pressure and high temperature of steam and flue gas. The common cause of any metallurgical failure of a …
C Magnus, A Pardeshi - Engineering Failure Analysis, 2024 - Elsevier
This study presents an investigation into the failure of a superheater tube. To pinpoint the primary cause of failure, a range of destructive and non-destructive analyses were …
R Kumar, A Sharma, P Tewari - International Journal of …, 2012 - growingscience.com
In recent years, the availability of power plants has become increasingly important issue in most developed and developing countries. This paper aims to propose a methodology …
A Firouzeh, K Ranjbar, SML Baghal, AH Kaidan… - Engineering Failure …, 2018 - Elsevier
This paper presents the results of an investigation into the failure of steam boiler tubes in a liquefied gas treatment plant. The failure appeared in the form of a window rupture in the …
Welding is the primary joining-process, produced the heat affected zone which is mostly damaged severely because of prolonged period particularly in corrosive environment. Most …
Liquid level in a pressure vessel can be monitored through the sight ports. Since a sight port is the assembly of various components (eg, body frame, gasket, sight glass, cover frame …
PG Rousseau, EZ Gwebu - Heat Transfer Engineering, 2019 - Taylor & Francis
ABSTRACT A network approach was used to develop a thermofluid process model of a cross-flow primary superheater heat exchanger with complex flow arrangement in the …
R Kumar - Decision Science Letters, 2014 - m.growingscience.com
The long term operation and planning of power plant depend upon an effective availability analysis and assessment of various systems in the plant concerned. The plant is expected to …