High-density versus low-density mapping in ablation of atypical atrial flutter

JC Balt, MN Klaver, BK Mahmoodi, VF Van Dijk… - Journal of Interventional …, 2021 - Springer
Purpose Ablation of atypical atrial flutter (AAFL) can be challenging. High-density (HD)
mapping of ablation targets may potentially increase procedural success and freedom from …

Epicardial connections after a conventional pulmonary vein antrum isolation in patients with atrial fibrillation

E Nyuta, M Takemoto, T Sakai, Y Antoku, T Mito… - Circulation …, 2022 - jstage.jst.go.jp
Background: The existence of epicardial connection (s)(ECs) between the pulmonary veins
(PVs) and atrium may hinder establishing a complete PV antrum isolation (AI)(PVAI) in …

Circle method for robust estimation of local conduction velocity high-density maps from optical mapping data: Characterization of radiofrequency ablation sites

JG Siles-Paredes, CJ Crowley, FH Fenton… - Frontiers in …, 2022 - frontiersin.org
Conduction velocity (CV) slowing is associated with atrial fibrillation (AF) and reentrant
ventricular tachycardia (VT). Clinical electroanatomical mapping systems used to localize AF …

High density mapping of complex atrial tachycardia in patients after cardiac surgery

L Fu, Y Xue - Pacing and Clinical Electrophysiology, 2023 - Wiley Online Library
To provide an overview of the current application of high‐density mapping (HDM) in the
mechanism of complex atrial tachycardias (ATs). Complex ATs are frequently scar‐related …

[HTML][HTML] Advisor high-definition HD Grid catheter for mapping accessory pathways in pediatrics

M Nguyen, JC von Alvensleben, M Runciman… - HeartRhythm Case …, 2020 - Elsevier
Intracardiac mapping of accessory pathways has continued to evolve and contribute to high
success rates for catheter ablations in pediatrics, ranging from 78% to 98%. 1, 2, 3 With 3 …

High-density electroanatomic mapping with grid catheter in pediatrics and congenital heart disease

JC von Alvensleben, A Sandhu, S Chang… - Journal of Interventional …, 2023 - Springer
Abstract Background The Advisor™ HD Grid mapping catheter (Abbott Laboratories;
Chicago, IL) allows for bipolar electrogram collection in both orthogonal and perpendicular …

[HTML][HTML] High-density Mapping Catheter (Advisor™ HD Grid) Usage for Intra-atrial Reentrant Tachycardia Ablation in Children and Young Adult Patients with …

Y Ergül, HC Kafalı, E Öztürk, S Gökalp… - Anatolian Journal of …, 2023 - ncbi.nlm.nih.gov
Background: We aimed to share our experience of intra-atrial reentrant tachycardia mapping
and ablation with a new grid-style multielectrode high-density mapping catheter (Advisor™ …

Management of macro-reentrant right atrial tachycardia around multiple leads aided by high-density mapping

M Bertini, D Mele, F Vitali, C Balla… - Reviews in …, 2022 - sfera.unife.it
Background: A 61-year-old male with Steinert Dystrophy and prior history of cardiac
implantable device complained of highly symptomatic right atrial tachycardia. Unresponsive …

[HTML][HTML] Uncovering “bipolar blindness” with high-density orthogonal mapping at the scar-related critical isthmus in repaired congenitally corrected transposition of the …

RM Bryant, K Allshouse, C Markert - HeartRhythm Case Reports, 2021 - Elsevier
Scar-mediated atrial and ventricular arrhythmias are leading indications for hospitalization
and risk factors for sudden cardiac death in the postoperative congenital heart population. 1 …

Editorial to utility of directional high‐density mapping catheter (Advisor HD Grid) in complex scar‐related atrial tachycardia

K Kumagai - Journal of arrhythmia, 2019 - pmc.ncbi.nlm.nih.gov
Multipolar mapping catheters such as the Pentaray®(Biosense Webster) and Orion®(Boston
Scientific) are often used for creating high-density maps rapidly in the patients with …