Surgeons' accuracy in achieving their desired acetabular component orientation

G Grammatopoulos, A Alvand, AP Monk, S Mellon… - JBJS, 2016 - journals.lww.com
Background: Wide variability in cup orientation has been reported. The aims of this study
were to determine how accurate surgeons are at orientating the acetabular component and …

A systematic review of all smart phone applications specifically aimed for use as a scoliosis screening tool

Q Naziri, J Detolla, W Hayes… - Journal of Long …, 2018 - dl.begellhouse.com
The scoliometer is an inclinometer commonly used in scoliosis screening. The device is
used during an Adam's forward bend test, in which a patient bends forward at the hips to …

Cost-effective mobile-based healthcare system for managing total joint arthroplasty follow-up

M Bitsaki, G Koutras, H Heep… - Healthcare informatics …, 2017 - synapse.koreamed.org
Objectives Long-term follow-up care after total joint arthroplasty is essential to evaluate hip
and knee arthroplasty outcomes, to provide information to physicians and improve …

Optimal position of lipped acetabular liners to improve stability in total hip arthroplasty—an intraoperative in vivo study

R Hau, J Hammeschlag, C Law, KK Wang - Journal of Orthopaedic …, 2018 - Springer
Background Lipped or elevated acetabular liners are frequently used in total hip arthroplasty
to improve stability. However, the optimal position of the lip is not known. The purpose of this …

Orthopedic surgeons' accuracy when orienting an acetabular cup. A comparison with untrained individuals

J Moreta, Ó Gayoso, D Donaire-Hoyas, J Roces-García… - Medicina, 2022 - mdpi.com
Background and Objectives: Previous studies demonstrated a huge variability among
surgeons when it comes to reproducing the position of an acetabular cup in total hip …

Reliability and criterion validity of measurements using a smart phone-based measurement tool for the transverse rotation angle of the pelvis during single-leg lifting

S Jung, O Kwon, I Jeon, U Hwang… - Physiotherapy theory and …, 2018 - Taylor & Francis
Objective: The purposes of this study were to determine the intra-rater test–retest reliability of
a smart phone-based measurement tool (SBMT) and a three-dimensional (3D) motion …

[HTML][HTML] Inter-and intra-observer reliability of scoliogauge app to assess the axial trunk rotation of scoliosis: Prospective reliability analysis study

MG Getnet, G Jember, B Janakiraman - International Journal of Surgery …, 2020 - Elsevier
Background Axial of trunk rotation is a key distinguishing feature in the diagnosis of
structural scoliosis. The non-affordability, high cost, and non-availability of clinical …

Smart Drill for a Streamlined Estimation of the Drilling Angle and Channel Length in Orthopedic Surgical Procedures

A Ivanišević, Z Boban, J Jurić, K Vukojević - Bioengineering, 2024 - mdpi.com
The estimation of distances and angles is a routine part of an orthopedic surgical procedure.
However, despite their prevalence, these steps are most often performed manually, heavily …

Evaluation of the smartphone for measurement of femoral rotational deformity

YF Shen, JH Huang, XL Li, H Gao - ANZ Journal of Surgery, 2019 - Wiley Online Library
Background A novel measurement technique has been designed to assess femoral rotation
deformation. The purpose of this study was to evaluate smartphone‐aided measurement …

Intraoperative correction of femoral rotational deformity using a conventional navigation system and a smartphone: a novel technique

JQ Cao, JH Huang, T Yuan, WT Jia… - Surgical …, 2017 - journals.sagepub.com
The intraoperatively rotational control of femoral shaft fractures treated with a closed
intramedullary interlocking nailing is a challenging problem. A novel surgical technique that …