Vestibular implantation and the feasibility of fluoroscopy-guided electrode insertion

JJA Stultiens, AA Postma, N Guinand… - … Clinics of North …, 2020 - oto.theclinics.com
Vestibular Implantation and the Feasibility of Fluoroscopy-Guided Electrode Insertion -
Otolaryngologic Clinics of North America Skip to Main Content Skip to Main Menu Advertisement …

Contemporary imaging of auditory implants

SEJ Connor - Clinical Radiology, 2018 - Elsevier
There have been significant advances in the diversity and effectiveness of hearing
technologies in recent years. Implanted auditory devices may be divided into those that …

Toward neural health measurements for cochlear implantation: The relationship among electrode positioning, the electrically evoked action potential, impedances and …

L Lambriks, M van Hoof, J Debruyne… - Frontiers in …, 2023 - frontiersin.org
Introduction Estimating differences in neural health across different sites within the individual
cochlea potentially enables clinical applications for subjects with a cochlear implant. The …

Imaging-based frequency mapping for cochlear implants–Evaluated using a daily randomized controlled trial

L Lambriks, M van Hoof, J Debruyne… - Frontiers in …, 2023 - frontiersin.org
Background Due to variation in electrode design, insertion depth and cochlear morphology,
patients with a cochlear implant (CI) often have to adapt to a substantial mismatch between …

A new slim modiolar electrode array for cochlear implantation: a radiological and histological study

M Iso-Mustajärvi, H Matikka, F Risi, S Sipari… - Otology & …, 2017 - journals.lww.com
Background: Hearing and structure preservation is the goal of cochlear implantation for
advanced hearing outcomes. Currently, this is most consistently achieved with thin lateral …

The insertion results of a mid-scala electrode assessed by MRI and CBCT image fusion

S Sipari, M Iso-Mustajärvi, H Löppönen… - Otology & …, 2018 - journals.lww.com
Objectives: To investigate the results of clinical surgical insertions with a Mid-scala array
(HIFocus Mid-Scala Electrode, HFms). Study Design: Consecutive retrospective case study …

Insertion characteristics and placement of the Mid-Scala electrode array in human temporal bones using detailed cone beam computed tomography

A Dietz, D Gazibegovic, J Tervaniemi… - European Archives of …, 2016 - Springer
The aim of this study was to evaluate the insertion results and placement of the new
Advanced Bionics HiFocus Mid-Scala (HFms) electrode array, inserted through the round …

The VertiGO! Trial protocol: A prospective, single-center, patient-blinded study to evaluate efficacy and safety of prolonged daily stimulation with a multichannel …

BL Vermorken, B Volpe, SCJ van Boxel, JJA Stultiens… - Plos one, 2024 - journals.plos.org
Background A combined vestibular (VI) and cochlear implant (CI) device, also known as the
vestibulocochlear implant (VCI), was previously developed to restore both vestibular and …

Characterization of cochlear, vestibular and cochlear-vestibular electrically evoked compound action potentials in patients with a vestibulo-cochlear implant

TAK Nguyen, S Cavuscens, M Ranieri… - Frontiers in …, 2017 - frontiersin.org
The peripheral vestibular system is critical for the execution of activities of daily life as it
provides movement and orientation information to motor and sensory systems. Patients with …

Effectiveness evaluation of China's water resource tax reform pilot and path optimization from the perspective of policy field

M Yang, M Zhou, C Zhang - Plos one, 2024 - journals.plos.org
The water resource tax reform played an important role in promoting sustainable
development in China. Subsequent to the seven-year reform, the effectiveness evaluation of …