Wind generators ferroresonance overvoltage protection methods: A review

M Hesami, M Bigdeli, MA Fatemi… - 2023 8th International …, 2023 - ieeexplore.ieee.org
Ferroresonance, as a sustained transient phenomenon associated with excessive voltages
and currents, can cause severe consequences if not mitigated properly. In that regard …

The Principles of Controlled DC-Reactor Fault Current Limiter for Battery Energy Storage Protection

A Heidary, M Popov, A Moghim… - IEEE Transactions on …, 2023 - ieeexplore.ieee.org
The significance of battery energy storage systems (BESSs) technology has been growing
rapidly, mostly due to the need for microgrid applications and the integration of renewables …

Multifaceted Functionalities of Bridge-Type DC Reactor Fault Current Limiters: An Experimentally Validated Investigation

B Behdani, A Moghim, S Mousavi, M Soltanfar… - Energies, 2024 - mdpi.com
With the ongoing expansion and interconnection of electrical power systems, alongside the
rapid proliferation of renewable distributed generations (DGs), the short-circuit extent in the …

Dual-function fault current limiter for electric vehicles protections

M Hesami, M Bigdeli, M Firouzi - International Journal of …, 2025 - Taylor & Francis
Electric vehicles (EVs) are becoming increasingly popular and the development of reliable
and efficient protection systems for their DC systems has become a pressing issue. In …

Definite time over-current protection on transmission line using MATLAB/Simulink

TA Taha, HI Zaynal, AST Hussain, H Desa… - Bulletin of Electrical …, 2024 - beei.org
This paper has investigated the application of the definite time over-current (DTOC) which
reacts to protect the breaker from damage during the occurrence of over-current in the …

Analysis and experimental tests of a solid-state fault current limiter

A Bitencourt, C Nogueira, G dos Santos, DHN Dias… - Electrical …, 2023 - Springer
The increase in distribution power demand and distributed generation may lead to a rise in
power substation fault current levels. One possible solution to this problem is the use of a …

Optimal circuit breaker allocation strategy in DC transmission-connected systems

B Kim, I Kim - Scientific Reports, 2024 - nature.com
The purpose of this study is to provide data for the best possible circuit breaker allocation in
power grids with HVDC transmission while taking circuit breaker failure into account. The …

[HTML][HTML] Study on the effect of arc chamber structures on the post-arc characteristics of generator circuit breaker

J Yin, Y Zhao, J Duan, S Liang - Electric Power Systems Research, 2024 - Elsevier
A generator circuit breaker (GCB) is installed at the outlet of generator. However, large-
capacity GCBs are highly prone to post-arc thermal breakdown during the breaking process …

Thermal analysis of the HTS transformer in the fault current condition considering the tape roughness effect

M Mahamed, S Seyyedbarzegar - Physica C: Superconductivity and its …, 2024 - Elsevier
High temperature superconducting (HTS) transformers have many advantages over
conventional transformers in terms of volume, weight, and total efficiency. However, fault …

A simplified control parameter optimisation method of the hybrid modular multilevel converter in the medium‐voltage DC distribution network for improved stability …

J Xu, Q Xiao, H Jia, Y Mu, Y Jin, W Lu… - IET Energy Systems …, 2024 - Wiley Online Library
To improve the stability of the hybrid modular multilevel converter (MMC), a simplified
dominant mode‐based control parameter optimisation method of the hybrid MMC system is …