[HTML][HTML] Biotribology of artificial hip joints

F Di Puccio, L Mattei - World journal of orthopedics, 2015 - ncbi.nlm.nih.gov
Hip arthroplasty can be considered one of the major successes of orthopedic surgery, with
more than 350000 replacements performed every year in the United States with a constantly …

Advances in tribological testing of artificial joint biomaterials using multidirectional pin-on-disk testers

D Baykal, RS Siskey, H Haider, V Saikko… - Journal of the …, 2014 - Elsevier
The introduction of numerous formulations of Ultra-high molecular weight polyethylene
(UHMWPE), which is widely used as a bearing material in orthopedic implants, necessitated …

Quantification of the effect of cross-shear on the wear of conventional and highly cross-linked UHMWPE

L Kang, AL Galvin, TD Brown, Z Jin, J Fisher - Journal of biomechanics, 2008 - Elsevier
A computational model has been developed to quantify the degree of cross-shear of a
polyethylene pin articulating against a metallic plate, based on the direct simulation of a …

Predicting the polyethylene wear rate in pin-on-disc experiments in the context of prosthetic hip implants: Deriving a data-driven model using machine learning …

A Borjali, K Monson, B Raeymaekers - Tribology international, 2019 - Elsevier
Abstract Pin-on-disc (PoD) experiments are widely used to quantify and rank wear of
different material couples for prosthetic hip implant bearings. However, polyethylene wear …

In vitro evaluation of artificial joints: a comprehensive review

G Shen, JF Zhang, FZ Fang - Advances in Manufacturing, 2019 - Springer
Abstract Development of artificial joints is a great progress for joint replacement operations
of human being, but the short longevity of prostheses has concerned both industries and …

Bio-tribological studies of Structalit/UHMWPE composites as an alternative to UHMWPE for hip joint application

JK Hirwani, SK Sinha - Wear, 2023 - Elsevier
In this study, epoxy based composites are evaluated for their mechanical and bio-
tribological properties to find an alternative to UHMWPE liner material for hip joints …

Finite element analysis of polyethylene wear in total hip replacement: A literature review

L Wang, G Isaac, R Wilcox, A Jones… - Proceedings of the …, 2019 - journals.sagepub.com
Evaluation and prediction of wear play a key role in product design and material selection of
total hip replacements, because wear debris is one of the main causes of loosening and …

A comparative study of wear laws for soft-on-hard hip implants using a mathematical wear model

L Mattei, F Di Puccio, E Ciulli - Tribology international, 2013 - Elsevier
Wear of UHMWPE acetabular components is the most serious threat to the long-term
success of hip replacements. Consequently numerical and experimental wear simulations …

Enhanced computational modelling of UHMWPE wear in total hip joint replacements: The role of frictional work and contact pressure

F Liu, Y He, Z Gao, D Jiao - Wear, 2021 - Elsevier
Hip joint replacements using highly cross-linked ultra-high-molecular-weight polyethylene
(UHMWPE) as a bearing material offer an effective treatment to arthritis. However, the …

Effect of crosslinking and Pt–Zr quasicrystal fillers on the mechanical properties and wear resistance of UHMWPE for use in artificial joints

CJ Schwartz, S Bahadur, SK Mallapragada - Wear, 2007 - Elsevier
The use of artificial joints is common for restoration of comfort and functionality in joints that
have been afflicted with cartilage loss due to disease or injury. These implants incorporate …