[HTML][HTML] A comparative study on the influence of probe placement on quality assurance measurements in B-mode ultrasound by means of ultrasound phantoms

A Scorza, S Conforto, C d'Anna… - The open biomedical …, 2015 - ncbi.nlm.nih.gov
To check or to prevent failures in ultrasound medical systems, some tests should be
scheduled for both clinical suitability and technical functionality evaluation: among them …

A novel approach to a phantom based method for maximum depth of penetration measurement in diagnostic ultrasound: a preliminary study

A Scorza, G Lupi, SA Sciuto, F Bini… - 2015 IEEE …, 2015 - ieeexplore.ieee.org
In the present work a new approach for maximum depth of ultrasound signal visualization
has been proposed by means of a tissue mimicking phantoms: the novel method is based …

Image quality assurance for B-mode diagnostic ultrasound: Kiviat-based protocol first application

G Fiori, M Schmid, J Galo, S Conforto… - … on Metrology for …, 2024 - ieeexplore.ieee.org
To date, Quality Assurance (QA) for diagnostic ultrasound is not mandatory despite the
continuous research in the field. Limits associated with visually assessed tests and the lack …

Breast ultrasound technology and performance evaluation of ultrasound equipment: B-mode

E Sassaroli, A Scorza, C Crake… - IEEE transactions on …, 2016 - ieeexplore.ieee.org
Ultrasound (US) has become increasingly important in imaging and image-guided
interventional procedures. In order to ensure that the imaging equipment performs to the …

[PDF][PDF] A preliminary study on a novel phantom based method for performance evaluation of clinical Colour Doppler systems

A Scorza, D Pietrobon, F Orsini, SA Sciuto - Proc. of the 22nd IMEKO TC4 …, 2017 - imeko.org
Ultrasound Colour Flow is an imaging technique that combines velocity with anatomical
information obtained by means of ultrasonic Doppler techniques and pulse-echo methods …

A preliminary study on the validation of anautomatic measurement method for functional reach assessment by stereophotogrammetry

C D'Anna, A Scorza, M Schmid, F Orsini… - 2017 IEEE …, 2017 - ieeexplore.ieee.org
In this work a preliminary study is proposed to assess the validity of an automatic and low
cost measurement method for Functional ReachTest (FRT) implementation. To this aim FRT …

Use of phantoms and test objects for local dynamic range evaluation in medical ultrasounds: A preliminary study

A Scorza, F Orsini, SA Sciuto - 2017 IEEE International …, 2017 - ieeexplore.ieee.org
In the ultrasound image the relationship between echo amplitudes and gray levels is
expressed by means of the Grayscale Mapping Function (GMF), that is the greyscale transfer …

[PDF][PDF] Uncertainty Evaluation of a Method for the Functional Reach Test Evaluation by means of Monte-Carlo Simulation

F Orsini, S Scena, C D'Anna, A Scorza… - Proceedings of the …, 2017 - imeko.org
The Functional Reach Test (FRT) is a simple, portable, clinically accepted tool that is used to
measure semi-static balance. In a recent study, video recordings and software …

Development of a bio-inspired mechatronic chest wall simulator for evaluating the performances of opto-electronic plethysmography

C Massaroni, E Schena, F Bastianini… - The open …, 2014 - pmc.ncbi.nlm.nih.gov
Instrumented gait analysis based on optoelectronic systems is an expensive technique used
to objectively measure the human movement features and it is generally considered as the …

Small-animal 360-deg fluorescence diffuse optical tomography using structural prior information from ultrasound imaging

PA Lo, SP Su, HK Chiang - Journal of Biomedical Optics, 2020 - spiedigitallibrary.org
We demonstrate dual modality of free-space fluorescence diffuse optical tomography
(FDOT) and handheld ultrasound (US) imaging to reveal both functional and structural …