[HTML][HTML] gr-MRI: A software package for magnetic resonance imaging using software defined radios

CJ Hasselwander, Z Cao, WA Grissom - Journal of Magnetic Resonance, 2016 - Elsevier
The goal of this work is to develop software that enables the rapid implementation of custom
MRI spectrometers using commercially-available software defined radios (SDRs). The …

Transmit array spatial encoding (TRASE) using broadband WURST pulses for RF spatial encoding in inhomogeneous B0 fields

JP Stockmann, CZ Cooley, B Guerin, MS Rosen… - Journal of Magnetic …, 2016 - Elsevier
Abstract Transmit Array Spatial Encoding (TRASE) is a promising new MR encoding method
that uses transmit RF (B 1+) phase gradients over the field-of-view to perform Fourier spatial …

Magnetic resonance imaging using a nonuniform Bo (NuBo) field-cycling magnet

K Selvaganesan, Y Wan, Y Ha, B Wu, K Hancock… - Plos one, 2023 - journals.plos.org
Magnetic resonance imaging (MRI) is a powerful noninvasive diagnostic tool with superior
soft tissue contrast. However, access to MRI is limited since current systems depend on …

Practical method for RF pulse distortion compensation using multiple square pulses for low-field MRI

Y Ha, K Selvaganesan, B Wu, K Hancock, C Rogers III… - Plos one, 2022 - journals.plos.org
Since recovery time of the RF coil is long at low field MRI, the rising and the ring-down times
of the square pulse are also long, which means the applied sinc pulse can easily be …

Bloch-Siegert phase-encoded MRI with a single RF coil and frequency-swept pulses

CJ Hasselwander, WA Grissom - … of the 25th Annual Meeting of …, 2017 - archive.ismrm.org
RF encoding using the Bloch-Siegert shift has the potential to replace conventional gradient
encoding with cheaper RF gradients, and can directly replace gradient pulsing in common …

Phase encoding with Bloch-Siegert effect using parallel transmit

Y Wan, M Qiu, G Galiana… - Proc. Intl. Soc. Mag …, 2017 - archive.ismrm.org
A gradient-free, Bloch-Siegert effect based nonlinear spatial encoding scheme was
introduced for silent scanning and to eliminate gradient-induced eddy currents in …

Methods for spatially encoding magnetic resonance signals with swept radio frequency (RF) pulses applied with RF spatial phase gradients

LL Wald, CZ Cooley, J Stockmann, B Guerin… - US Patent …, 2020 - Google Patents
Described here are systems and methods for performing magnetic resonance imaging
(“MRI”) using radio frequency (“RF”) phase gradients to provide spatial encoding of …

Design of frequency division duplex RF system for frequency encoding using Bloch-Siegert shift

Y Ha, K Selvaganesan, C Rogers III, B Wu… - archive.ismrm.org
In this work, we designed a frequency division duplex RF system for frequency encoding
using Bloch-Siegert shift at very low field, with a modification of dual-band pass filters …

Design and comparison of the RF systems for frequency encoding by nonlinear Bloch-Siegert shift at low field MRI

Y Ha, K Selvaganesan, B Wu, C Rogers III… - archive.ismrm.org
To achieve frequency encoding using Bloch-Siegert shift, the off-resonance pulse and signal
reception would need to take place simultaneously. In this work we describe two methods to …