[PDF][PDF] Two-port network analyzer calibration using an unknown “thru”

I ANALYZER - IEEE Microwave and guided wave letters, 1992 - av.it.pt
A procedure performed by using a generic two port reciprocal network instead of a standard
thru in a full two-port error correction of an automatic network analyzer is presented …

[PDF][PDF] Network analyzer error models and calibration methods

D Rytting - White Paper, September, 1998 - Citeseer
This is a generic block diagram of a 4 channel network analyzer. The source can be
switched to excite port-1 or port-2 of the device under test (DUT). The switch also provides a …

[PDF][PDF] VNA calibration

A Rumiantsev, N Ridler - IEEE Microwave magazine, 2008 - anlage.umd.edu
It was during the late 1950s that the need for reliable measurement, and therefore reliable
measurement standards, at RF and microwave frequencies began to emerge. This led to the …

Recent advances in real-time load-pull systems

V Teppati, A Ferrero, U Pisani - IEEE Transactions on …, 2008 - ieeexplore.ieee.org
In this paper, some of the latest advances in real-time load-pull technologies will be
described. A recently introduced ultralow-loss directional coupler, which has been designed …

VNA Tools II: S-parameter uncertainty calculation

M Wollensack, J Hoffmann… - 79th ARFTG …, 2012 - ieeexplore.ieee.org
This paper describes a software, METAS VNA Tools II, which is designed to compute
uncertainties of coaxial S-parameter measurements. A bottom-up concept is used. Thus …

A new implementation of a multiport automatic network analyzer

A Ferrero, U Pisani, KJ Kerwin - IEEE Transactions on …, 1992 - ieeexplore.ieee.org
A generalized multiport network analyzer implemented using commercially available
hardware is presented. Measurement calibration is accomplished through a novel …

Robust SOLT and alternative calibrations for four-sampler vector network analyzers

JA Jargon, RB Marks, DK Rytting - IEEE transactions on …, 1999 - ieeexplore.ieee.org
This paper assesses the accuracy of several proposed lumped-element calibration
techniques for four-sampler vector network analyzers in the face of imperfectly defined …

A novel calibration algorithm for a special class of multiport vector network analyzers

A Ferrero, V Teppati, M Garelli… - IEEE transactions on …, 2008 - ieeexplore.ieee.org
A new error model for a special class of multiport vector network analyzers (VNAs) is
presented in this paper. This model can be applied to multiport network analyzers with …

Influence of different configurations of nonideal calibration standards on vector network analyzer performance

U Stumper, T Schrader - IEEE Transactions on Instrumentation …, 2012 - ieeexplore.ieee.org
To perform system error correction of a microwave vector network analyzer (VNA), several
calibration procedures are applied, several of which are derived from the well-known short …

VNA tools II: Calibrations involving eigenvalue problems

M Wollensack, J Hoffmann, D Stalder… - 2017 89th ARFTG …, 2017 - ieeexplore.ieee.org
Many calibration algorithms for vector network analyzers using partially unknown standards