The current role of robotics in total hip arthroplasty

B Kayani, S Konan, A Ayuob, S Ayyad… - EFORT Open …, 2019 - eor.bioscientifica.com
Robotic total hip arthroplasty (THA) improves accuracy in achieving the planned acetabular
cup positioning compared to conventional manual THA. Robotic THA improves precision …

The effect of bearing surface on risk of periprosthetic joint infection in total hip arthroplasty: a systematic review and meta-analysis

AT Hexter, SM Hislop, GW Blunn… - The Bone & Joint …, 2018 - boneandjoint.org.uk
Aims Periprosthetic joint infection (PJI) is a serious complication of total hip arthroplasty
(THA). Different bearing surface materials have different surface properties and it has been …

Reasons for revision: primary total hip arthroplasty mechanisms of failure

G Kelmer, AH Stone, J Turcotte… - JAAOS-Journal of the …, 2021 - journals.lww.com
Background: This study aimed to examine the major reasons for total hip arthroplasty (THA)
failure and temporal patterns in THA revisions. Methods: A retrospective chart review was …

Temporal trends and survivorship of total hip arthroplasty in very young patients: a study using the National Joint Registry data set

D Metcalfe, N Peterson, JM Wilkinson… - The Bone & Joint …, 2018 - boneandjoint.org.uk
Aims The aim of this study was to describe temporal trends and survivorship of total hip
arthroplasty (THA) in very young patients, aged≤ 20 years. Patients and Methods A …

Aseptic revision total hip arthroplasty in the elderly: quantifying the risks for patients over 80 years old

P Bovonratwet, R Malpani, TD Ottesen… - The Bone & Joint …, 2018 - boneandjoint.org.uk
Aims The aim of this study was to compare the rate of perioperative complications following
aseptic revision total hip arthroplasty (THA) in patients aged≥ 80 years with that in those …

The risk of cardiac failure following metal-on-metal hip arthroplasty

SA Sabah, JC Moon, S Jenkins-Jones… - The Bone & Joint …, 2018 - boneandjoint.org.uk
Aims The aim of this study was to determine whether patients with metal-on-metal (MoM)
arthroplasties of the hip have an increased risk of cardiac failure compared with those with …

What is appropriate surveillance for metal-on-metal hip arthroplasty patients? A clinical update

GS Matharu, A Judge, A Eskelinen, DW Murray… - Acta …, 2018 - Taylor & Francis
The unexpected high revision rates of large-diameter (femoral head sizes of 36 mm or
greater) metal-on-metal hip arthroplasties (MoMHAs) have led to worldwide regulatory …

Case report: Formation and recurrence of inflammatory pseudotumor after metal-on-metal hip arthroplasty

M Min, C Xing, P Xu, X Wei, L Fan - Frontiers in Medicine, 2024 - frontiersin.org
The metal-on-metal (MoM) artificial hip joint is a prosthesis used in early hip arthroplasty,
particularly for hip resurfacing and total hip arthroplasty. However, abrasion and corrosion of …

[HTML][HTML] Same survival but higher rate of osteolysis for metal-on-metal Ultamet versus ceramic-on-ceramic in patients undergoing primary total hip arthroplasty after 8 …

Y Higuchi, T Seki, Y Takegami, D Komatsu… - … & Traumatology: Surgery …, 2018 - Elsevier
Background To avoid wear-induced osteolysis, ceramic-on-ceramic (CoC) and metal-on-
metal (MoM) bearings have been developed. At present, there are no direct material related …

Perioperative Complications after Hip and Knee Revision Arthroplasty in the over 80 Years Old Population: A Retrospective Observational Case–Control Study

V Di Matteo, M Di Pilla, F La Camera… - Journal of Clinical …, 2023 - mdpi.com
Background: The number of joint revision arthroplasties has increased in the elderly
population, which is burdened by several perioperative risks. Methods: Patients who …