Shear strength criteria for design of RC beam–column joints in building codes

K Parate, R Kumar - Bulletin of Earthquake Engineering, 2019 - Springer
The paper presents a comprehensive review on shear strength provisions of RC beam–
column joint in various national codes viz. ACI 318-2014, NZS 3101-1: 2006, EN 1998-1 …

A new model to simulate joint shear behavior of poorly detailed beam–column connections in RC structures under seismic loads, Part I: Exterior joints

A Sharma, R Eligehausen, GR Reddy - Engineering Structures, 2011 - Elsevier
A new model that can simulate the shear behavior of reinforced concrete connections in
structures subjected to seismic loads is proposed. The model uses limiting principal tensile …

Modelling exterior unreinforced beam‐column joints in seismic analysis of non‐ductile RC frames

MT De Risi, P Ricci… - Earthquake Engineering & …, 2017 - Wiley Online Library
The seismic response of non‐ductile reinforced concrete (RC) buildings can be affected by
the behaviour of beam‐column joints involved in the failure mechanism, especially in typical …

[PDF][PDF] Seismic assessment of RC exterior beam-column joints and retrofit with haunches using post-installed anchors

G Genesio - University of Stuttgart, 2012 - academia.edu
The assessment of the shear strength of two dimensional (2D) reinforced concrete (RC)
exterior beam-column joints is an open issue and its solution is still a point of discussion in …

Prediction of the shear strength of RC beam-column joints using new ANN formulations

JH Haido - Structures, 2022 - Elsevier
Beam-column joint is a key part for reinforced concrete (RC) frame building structures under
the impact of severe lateral actions of seismic or wind loading. Prior works indicate that there …

Cyclic tests on external RC beam-column joints: role of seismic design level and axial load value on the ultimate capacity

A Masi, G Santarsiero, D Nigro - Journal of Earthquake Engineering, 2013 - Taylor & Francis
A wide experimental program on beam-column RC joints carried out in the framework of the
DPC-Reluis Project (DPC: Department of Civil Protection, Reluis: Network of University …

Quasi-static cyclic performance of RC exterior beam-column joint assemblages strengthened with geosynthetic materials

S Majumder, S Saha - Structures, 2021 - Elsevier
The beam-column joints are the most critical and vulnerable part of the RC framed structures
when subjected to earthquake load. The objective of the present study is to investigate the …

Seismic performance of GFRP-RC exterior beam–column joints with lateral beams

SK Ghomi, E El-Salakawy - Journal of Composites for Construction, 2016 - ascelibrary.org
Six full-scale specimens were constructed and tested under reversal cyclic loading to study
the seismic behavior of exterior glass-fiber-reinforced-polymer (GFRP) reinforced concrete …

Strut-and-tie modelling for the analysis and design of RC beam-column joints

W Kassem - Materials and Structures, 2016 - Springer
Beam-column joints have been recognised as one of the potentially weaker elements of
reinforced concrete moment-resisting frame structures when subjected to seismic lateral …

HPFRC jacketing of non seismically detailed RC corner joints

C Beschi, P Riva, G Metelli, A Meda - Journal of Earthquake …, 2015 - Taylor & Francis
In this article, the effectiveness of a High-Performance Fiber-Reinforced Concrete (HPFRC)
jacket for the seismic retrofitting of existing RC corner beam-column joints is experimentally …