Validation for photon beams in the energy range of 20–1000 keV

D Terribilini, MK Fix, D Frei, W Volken… - Medical …, 2010 - Wiley Online Library
Purpose: In high energy teletherapy, is known to be a very accurate and efficient Monte
Carlo (MC) code. In principle, the MC method is also a powerful dose calculation tool in …

Implementation of a brachytherapy Ir-source in an in-house system and comparison of simulation results with EGSnrc, VMC++ and PIN

D Terribilini, P Manser, D Frei, W Volken… - Journal of Physics …, 2007 - iopscience.iop.org
Today's brachytherapy planning systems perform computation of energy deposition in
patients by assuming homogeneous water medium and multiplicative transmission factors …

Brachytherapy organ dose estimation using Monte Carlo simulations of realistic patient models

S Morató, B Juste, S Peris, R Miró… - 2018 40th Annual …, 2018 - ieeexplore.ieee.org
Radiation Therapy Planning Systems (RTPS) currently used in hospitals contain algorithms
based on deterministic simplifications that do not properly consider electrons lateral …

Determination of dosimetric parameters for shielded Gd source in prostate cancer brachytherapy

M Ghorbani, B Khajetash, N Ghatei… - Radiology and …, 2017 - sciendo.com
Background. Interstitial rotating shield brachytherapy (I-RSBT) is a recently developed
method for treatment of prostate cancer. In the present study TG-43 dosimetric parameters of …

Photon activation therapy: a Monte Carlo study on dose enhancement by various sources and activation media

M Bakhshabadi, M Ghorbani, AS Meigooni - Australasian physical & …, 2013 - Springer
In the present study, a number of brachytherapy sources and activation media were
simulated using MCNPX code and the results were analyzed based on the dose …

A Monte Carlo interstitial brachytherapy study for AAPM TG-43 dose calculation formalism in heterogeneous media

G Song, Y Wu - 2008 2nd International Conference on …, 2008 - ieeexplore.ieee.org
The precision of AAPM TG-43 dose calculation formalism in heterogeneous media has been
studied based on the survey and evaluation of the status of interstitial brachytherapy. After a …

Henschke 近接治療裝療管於商用治療計畫與蒙地卡羅方法間的劑量分布比較

游佩潔, 吳錦榕, 雷德, 蕭世禎, 粘心華 - 放射治療與腫瘤學, 2012 - airitilibrary.com
目的: Henschke 裝療管於近接治療造成的劑量擾動, 在最近幾年內受到關注,
為了瞭解劑量計算時有無含金屬遮蔽物, 對於劑量影響程度, 本研究將針對於Ir-192 …

Presentation of a matrix-based method to calculate dose distribution in brachytherapy with photon-emitting sources

M Ghorbani, A Mozaffari… - Journal of Cancer …, 2019 - journals.lww.com
Aim of Study: The report of the task group number 43 (TG-43) of AAPM has been known as
the most common method to obtain the dose distribution around brachytherapy sources. The …

Dose assessment for brachytherapy with Henschke applicator

PC Yu, TC Chao, CJ Tung, CJ Wu, CC Lee - Radiation measurements, 2011 - Elsevier
Dose perturbation caused by the Henschke applicator is a major concern for the
brachytherapy planning system (BPS) in recent years. To investigate dose impact owing to …

Investigation of the Effects of Tissue Inhomogeneities on the Dosimetric Parameters of a Cs-137 Brachytherapy Source using the MCNP4C Code

M Zehtabian, R Faghihi, S Sina… - Iranian journal of …, 2010 - journals.mums.ac.ir
Introduction: Brachytherapy is the use of small encapsulated radioactive sources in close
vicinity of tumors. Various methods are used to obtain the dose distribution around …