Tracing harmonic distortion and voltage unbalance in secondary radial distribution networks with photovoltaic uncertainties by an iterative multiphase harmonic load …

JC Hernandez, FJ Ruiz-Rodriguez, F Jurado… - Electric Power Systems …, 2020 - Elsevier
Secondary radial distribution networks (SRDNs) have been increasingly affected by the
uncertainties of harmonic sources associated with photovoltaic (PV) systems. The …

Deterministic aggregated harmonic source models for harmonic analysis of large medium voltage distribution networks

A Bosovic, H Renner, A Abart, E Traxler… - IET Generation …, 2019 - Wiley Online Library
Modelling of harmonics in large medium voltage (MV) distribution networks has so far been
a challenge due to the presence of a large number of harmonic sources contributing to total …

Analysis of the impact of different distributed generator technologies on harmonic voltages

E MELIĆ, A BOSOVIĆ, M MUSIĆ - REVUE ROUMAINE DES …, 2023 - journal.iem.pub.ro
While distributed generators (DGs) can reduce carbon dioxide emissions, they can also
cause disturbances and lead to power quality (PQ) issues, with harmonic voltages being an …

Optimal placement of power quality monitors by accounting for several key power quality disturbances

A Bosovic, H Renner, H Friedl, A Abart, E Traxler… - Electrical …, 2024 - Springer
Many distribution system operators are installing PQ monitoring systems in their medium-
voltage networks. Installation of PQ monitors in all the nodes of the network is uneconomical …

[PDF][PDF] Stochastic harmonic emission model of aggregate residential customers

AMB Castañeda - 2017 - researchgate.net
The concern about the causes and effects of harmonics in power systems began in the
1920's when distorted voltage and current waveforms were observed on power lines for the …

Parameter determination of coupled and decoupled admittance matrix methods of the Norton equivalent model for an air extractor

AM Peñaloza, G Osma-Pinto, G Ordóñez-Plata - Tecnura, 2022 - revistas.udistrital.edu.co
Metodología: Este artículo presenta el modelado en el dominio de la frecuencia de un motor
de inducción monofásico usado como extractor de aire silencioso (127 V, 60 Hz, 66 W), el …

[PDF][PDF] Modelling the propagation of harmonic voltages in large medium voltage distribution networks

A Bosovic, H Renner, A Abart, E Traxler, J Meyer… - 2019 - cired-repository.org
Harmonic voltages are important power quality (PQ) parameters, mainly caused by non-
linear loads that act as harmonic current sources in the network. Modelling the propagation …

Analysis of the impact of harmonics and a DG on a novel earth-fault location method in MV distribution networks with compensated neutral grounding

E Salhab, Q Lebourg, D Croteau… - 2023 IEEE PES …, 2023 - ieeexplore.ieee.org
Following a previous work regarding the fault location on Medium Voltage (MV) distribution
networks with compensated neutral grounding, a new study aims to assess the robustness …

[HTML][HTML] Determinación de parámetros de métodos de matriz de admitancia acoplada y desacoplada del modelo Equivalente Norton para extractor de aire

A Martínez-Peñaloza, G Osma-Pinto, G Ordóñez-Plata - Tecnura, 2022 - scielo.org.co
Contexto: Estudios realizados en redes de baja tensión han explorado el modelado de
cargas monofásicas lineales (como motores) y no lineales (como dispositivos basados en …

Calibration of a Harmonic State Estimation to Assess the Connection of Solar PV Systems in Distribution Networks

ADL Bermeo, DPG Bermeo, SPZ Asanza… - 2023 IEEE Seventh …, 2023 - ieeexplore.ieee.org
This paper presents an analysis of the distribution system harmonic behavior when a
photovoltaic (PV) system is connected at the low-voltage network. Through harmonic power …