Correcting lateral response artifacts from flatbed scanners for radiochromic film dosimetry

D Lewis, MF Chan - Medical physics, 2015 - Wiley Online Library
Purpose: A known factor affecting the accuracy of radiochromic film dosimetry is the lateral
response artifact (LRA) induced by nonuniform response of a flatbed scanner in the direction …

Energy dependence of the Gafchromic EBT4 film: Dose‐response curves for 70 kV, 6 MV, 6 MV FFF, 10 MV FFF, and 15 MV x‐ray beams

MF Chan, J Park, R Aydin, SB Lim - Medical physics, 2023 - Wiley Online Library
Background EBT4 was newly released for radiotherapy quality assurance to improve the
signal‐to‐noise ratio in radiochromic film dosimetry. It is important to know its dose …

A new form of the calibration curve in radiochromic dosimetry. Properties and results

M Tamponi, R Bona, A Poggiu, P Marini - Medical Physics, 2016 - Wiley Online Library
Purpose: This work describes a new form of the calibration curve for radiochromic dosimetry
that depends on one fit parameter. Some results are reported to show that the new curve …

[HTML][HTML] Patient-specific QA of spot-scanning proton beams using radiochromic film

MF Chan, CC Chen, C Shi, J Li, X Tang… - International journal of …, 2017 - ncbi.nlm.nih.gov
Radiochromic film for spot-scanning QA provides high spatial resolution and efficiency gains
from one-shot irradiation for multiple depths. However, calibration can be a tedious …

The physics of radiochromic process: one calibration equation for all film types

P Casolaro, L Campajola… - Journal of …, 2019 - iopscience.iop.org
A unique calibration equation for all radiochromic film types is proposed. The determination
of this equation comes from an analogy that the authors made between the radiochromic …

Dose comparison between Gafchromic film, XiO, and Monaco treatment planning systems in a novel pelvic phantom that contains a titanium hip prosthesis

N Ade, FCP du Plessis - Journal of Applied Clinical Medical …, 2017 - Wiley Online Library
The presence of metallic prostheses during external beam radiotherapy of malignancies in
the pelvic region has the potential to strongly influence the dose distribution to the target and …

Evaluation of dose accuracy in the near-surface region for whole breast irradiation techniques in a multi-institutional consortium

A Moncion, M Wilson, R Ma, R Marsh… - Practical Radiation …, 2022 - Elsevier
Purpose To assess the accuracy of dose calculations in the near-surface region for different
treatment planning systems (TPSs), treatment techniques, and energies to improve clinical …

A prototype, glassless densitometer traceable to primary optical standards for quantitative radiochromic film dosimetry

BS Rosen, CG Soares, CG Hammer… - Medical …, 2015 - Wiley Online Library
Purpose: To evaluate a prototype densitometer traceable to primary optical standards and
compare its performance to an EPSON Expression® 10000XL flatbed scanner (the Epson) …

Film dosimetry

S Mossahebi, N Hoshyar, R Khan… - Radiation Therapy …, 2021 - taylorfrancis.com
Film dosimeters provide two-dimensional measurement with high spatial resolution over a
large area. There are, in general, two types of films used as dosimeters: radiographic and …

Dose mapping of hard X-ray radiation due to runaway electrons in Alvand tokamak using combination of high-dose and low-dose level dosimeters

B Pourshahab, C Rasouli, D Iraji - Fusion Engineering and Design, 2023 - Elsevier
Tokamaks are one of the strongest types of hard x-ray (HXR) sources that always generate
energetic hard x-rays because of the bremsstrahlung radiation, when energetic runaway …