Flexural behavior of beam to column joints with or without an overlying concrete slab

B Mou, F Zhao, Q Qiao, L Wang, H Li, B He, Z Hao - Engineering Structures, 2019 - Elsevier
Composite action between a steel frame and an overlying slab plays an important role in the
structure design of a beam-column joint in a steel or composite framed structure. This …

Behaviour of flush end plate joints to concrete-filled steel tubular columns

JF Wang, LH Han, B Uy - Journal of Constructional Steel Research, 2009 - Elsevier
This paper presents the results of an experimental program for bolted moment connection
joints of circular or square concrete filled steel tubular (CFST) columns, and H-shaped steel …

Refined numerical modelling for the structural assessment of steel-concrete composite beam-to-column joints under seismic loads

C Amadio, C Bedon, M Fasan, MR Pecce - Engineering Structures, 2017 - Elsevier
This paper proposes a refined Finite-Element (FE) numerical approach to predict both global
and local behaviour of steel-concrete composite welded joints subjected to seismic loads …

Behaviour of composite joints with concrete encased CFST columns under cyclic loading: Experiments

FY Liao, LH Han, Z Tao - Engineering Structures, 2014 - Elsevier
Concrete-encased concrete filled steel tube (CFST) columns have been applied in some
real structures in recent years, where they were connected with reinforced concrete (RC) …

The effects of partial shear connection in composite flush end plate joints Part I—experimental study

HY Loh, B Uy, MA Bradford - Journal of Constructional Steel Research, 2006 - Elsevier
The experimental results of partial shear connection composite beams subjected to hogging
bending have been previously reported. An extension to this work which considers the …

Behaviour of bolted endplate composite joints to square and circular CFST columns

HT Thai, B Uy, F Aslani - Journal of Constructional Steel Research, 2017 - Elsevier
This paper presents the results of an experimental study on the structural performance of
blind bolted endplate composite connections to concrete filled steel tubular (CFST) columns …

Behaviour of composite beam–column flush end-plate connections subjected to low-probability, high-consequence loading

O Mirza, B Uy - Engineering Structures, 2011 - Elsevier
This paper aims to investigate the performance of beam–column flush end-plate
connections when using blind bolts. The paper studies the strength on medium rise …

Experimental study and numerical simulation analysis of the Bolted-Welded hybrid connection joint of steel frame under fire

S Fan, S Duan, S Zeng, Y Wu, R Ding - Structures, 2022 - Elsevier
As an important part of the steel frame structure, the bolted-welded hybrid connection joint
has a significant impact on the overall behavior of the structure and the prevention of …

Finite element modelling of blind bolted composite joints

HT Thai, B Uy - Journal of Constructional Steel Research, 2015 - Elsevier
This paper aims to develop a detailed three-dimensional finite element model to study the
behaviour of blind bolted endplate composite joints that connect composite beams to a …

Seismic behavior of blind bolted CFST frames with semi-rigid connections

J Wang, J Wang, H Wang - Structures, 2017 - Elsevier
To investigate seismic behavior and failure modes of blind bolted concrete-filled steel
tubular (CFST) frames with semi-rigid connections, an experimental study on two specimens …