Neutron production during the interaction of monoenergetic electrons with a Tungsten foil in the radiotherapeutic energy range

TG Soto-Bernal, A Baltazar-Raigosa… - Nuclear Instruments and …, 2017 - Elsevier
The electron, photon, and neutron spectra produced during the interaction between
monoenergetic electron beams (8, 10, 12, 15, and 18 MeV) and a 0.05 cm-thick tungsten …

Photoneutron dose estimation in GRID therapy using an anthropomorphic phantom: A Monte Carlo study

N Chegeni, AH Karimi, I Jabbari… - Journal of Medical …, 2018 - journals.lww.com
Background: In the past, GRID therapy was used as a treatment modality for the treatment of
bulky and deeply seated tumors with orthovoltage beams. Now and with the introduction of …

CubBonner–A novel passive neutron area monitor

A Baltazar-Raigosa, TG Soto-Bernal… - Applied Radiation and …, 2020 - Elsevier
Responses of a novel passive neutron area monitor, named CubBonner, were calculated.
The responses were estimated for sixty monoenergetic neutrons, from 10− 9 to 20 MeV, with …

Measurement of neutron dose in the compensator IMRT treatment

A Rezaian, HA Nedaie, N Banaee - Applied Radiation and Isotopes, 2017 - Elsevier
A radiation treatment delivery technique, intensity modulated radiation therapy (IMRT), has
found widespread use in the treatment of cancers. One of IMRT implementing methods is …

[PDF][PDF] Evaluation of neutron spectra and dose equivalent from a Varian 2100C/D Medical Linear Accelerator: Monte Carlo simulation and

S Razghandi, K Karimi-Shahri, MM Firoozabadi - Radioprotection, 2021 - academia.edu
In this study was carried out a review according to experimental and Monte Carlo studies in
the literature on the neutron production from 18 MV, Varian 2100C/D linac. The effects of …

The empirical mode decomposition-decision tree method to recognize the steady-state visual evoked potentials with wide frequency range

S Sadeghi, A Maleki - Journal of Medical Signals & Sensors, 2018 - journals.lww.com
Background: The empirical mode decomposition (EMD) is a technique to analyze the steady-
state visual evoked potential (SSVEP) which decomposes the signal into its intrinsic mode …

[PDF][PDF] Investigation of neutron contamination of flattening filter and flattening filter-free 10-MV photon beams in Elekta InfinityTM accelerator

S Yani, I Budiansah, FP Lestari, M Rhani… - Iranian Journal of …, 2020 - researchgate.net
Linear accelerator (Linac) operating above 8 MV produces photoneutrons whether it
operates in the electron or X-ray mode. Particle contaminations, neutrons, and electrons are …

Monitor Cubonner para medir la dosis equivalente ambiental en torno a los LINACs de uso médico

AB Raigosa, TGS Bernal, COT Cortés… - Memoria …, 2020 - revistas.uaz.edu.mx
El incremento de los casos de cáncer en la población mundial, ha propiciado un aumento
en el número de aceleradores lineales, o LINACs, como una alternativa para su tratamiento …

Bcs/Au response matrix

A Baltazar R, TG Soto B, A Garcia D, CO Torres C… - 2019 - inis.iaea.org
[en] The use and characterization of ionizing radiation, coupled with its technological
development in different areas of knowledge are constantly developing. In order to use …

Design of a passive area monitor to measure the H (10) of the neutrons produced in Linacs for medical use

A Baltazar R, CO Torres C, HR Vega C, JM Ortiz R… - 2018 - inis.iaea.org
[en] The increase in cancer cases in the world population has led to an increase in the
number of linear accelerators, or Linacs, as an alternative for their treatment. The …