Estimating dose delivery accuracy in stereotactic body radiation therapy: a review of in-vivo measurement methods

M Esposito, E Villaggi, S Bresciani, S Cilla… - Radiotherapy and …, 2020 - Elsevier
Stereotactic body radiation therapy (SBRT) has been recognized as a standard treatment
option for many anatomical sites. Sophisticated radiation therapy techniques have been …

[HTML][HTML] Novel methodologies for dosimetry audits: Adapting to advanced radiotherapy techniques

M Pasler, V Hernandez, N Jornet, CH Clark - Physics and Imaging in …, 2018 - Elsevier
With new radiotherapy techniques, treatment delivery is becoming more complex and
accordingly, these treatment techniques require dosimetry audits to test advanced aspects of …

[HTML][HTML] Two-dimensional real-time quality assurance dosimetry system using μ-Al2O3: C, Mg radioluminescence films

LF Nascimento, D Verellen, J Goossens… - Physics and imaging in …, 2020 - Elsevier
Background and purpose There is a continual need for more accurate and effective
dosimetric systems for quality assurance (QA) as radiotherapy evolves in complexity. The …

Sensitivity of the IQM transmission detector to errors of VMAT plans

G Razinskas, S Wegener, J Greber… - Medical Physics, 2018 - Wiley Online Library
Purpose The integral quality monitor (IQM) transmission detector is a wedge‐shaped large
area ionization chamber that reports a position‐weighted dose area product for each control …

Review of real time 2D Dosimetry in External Radiotherapy: Advancements and Techniques

L de Freitas Nascimento, A Gasparini - Radiation Measurements, 2024 - Elsevier
The objective of this paper is to provide a comprehensive review of the advancements and
techniques in real time two-dimensional (2D) dosimetry for external radiation therapy with …

A systematic evaluation of the error detection abilities of a new diode transmission detector

V Sarkar, A Paxton, J Kunz, M Szegedi… - Journal of applied …, 2019 - Wiley Online Library
Transmission detectors meant to measure every beam delivered on a linear accelerator are
now becoming available for monitoring the quality of the dose distribution delivered to the …

Assessment of a Therapeutic X-ray Radiation Dose Measurement System Based on a Flexible Copper Indium Gallium Selenide Solar Cell

DS Shin, TH Kim, JE Rah, D Kim, HJ Yang, SB Lee… - Sensors, 2022 - mdpi.com
Several detectors have been developed to measure radiation doses during radiotherapy.
However, most detectors are not flexible. Consequently, the airgaps between the patient …

Delta4 Discover transmission detector: A comprehensive characterization for in-vivo VMAT monitoring

E Petrucci, L Radici, VC Borca, S Ferrario, M Paolini… - Physica Medica, 2021 - Elsevier
Objective To investigate the dosimetric behaviour, influence on photon beam fluence and
error detection capability of Delta 4 Discover transmission detector. Methods The …

[PDF][PDF] 钨门主动控制与被动跟随的剂量学差异性分析

曹丽媛, 鞠永健, 李克新 - 中国辐射卫生, 2023 - zgfsws.com
目的分析动态调强放疗计划设计时固定铅门技术对剂量学参数的影响. 方法选取2020
年在本院放疗科行动态调强放射治疗鼻咽癌, 宫颈癌术后, 右侧乳腺癌根治术后患者各10 例 …

Error detection capability of a novel transmission detector: a validation study for online VMAT monitoring

M Pasler, K Michel, L Marrazzo… - Physics in Medicine …, 2017 - iopscience.iop.org
Error detection capability of a novel transmission detector: a validation study for online VMAT
monitoring - IOPscience Skip to content IOP Science home Accessibility Help Search Journals …