Discrete-time DC-link voltage and current control of a grid-connected inverter with lcl-filter and very small DC-link capacitance

O Kalmbach, C Dirscherl, CM Hackl - Energies, 2020 - mdpi.com
The paper presents a controller design for grid-connected inverters (GCI) with very small dc-
link capacitance that are coupled to the grid via an LCL filter. The usual controller designs …

Improved capacitor voltage feedforward for three-phase LCL-type grid-connected converter to suppress start-up inrush current

S Zhou, X Zou, D Zhu, L Tong, Y Kang - Energies, 2017 - mdpi.com
Three-phase active damping LCL-type grid-connected converters are usually used in
distributed power generation systems. However, serious inrush current will be aroused …

Analysis and design of voltage feedforward for stability and power quality of grid-tied inverter

G Wang, X Du, P Sun, HM Tai… - IECON 2017-43rd Annual …, 2017 - ieeexplore.ieee.org
In three-phase grid-tied inverter, grid voltage feedforward is helpful to improve grid-tied
power quality for strong grid condition. This paper found that the voltage feedforward had …

Harmonics performance and system stability evaluation between 18-pulse and LCL filter based active front end converters under weak grid condition

K Lee, W Yao, D Carnovale… - 2017 IEEE Energy …, 2017 - ieeexplore.ieee.org
Adjustable speed drives (ASDs) equipped with 18-pulse converter front end provide input
disturbance rejection and clean power quality in various practical applications. In recent …

Stability analysis of multiple grid-connected inverters using different feedback currents

D Carballo, E Escala, JC Balda - 2018 9th IEEE International …, 2018 - ieeexplore.ieee.org
Distributed generation is gaining greater penetration levels in distribution grids due to
government incentives for integrating distributed energy resources (DERs) and DER cost …

Design of active low pass filters to reduce harmonic current emission

D De Santis, M Chen - IECON 2017-43rd Annual Conference of …, 2017 - ieeexplore.ieee.org
The growing development of distributed generation and storage devices has allowed the
growth of micro-grids in low voltage and medium voltage grids. This caused the increase of …

Delay-Dependent Stability Analysis of Grid-tied Voltage Source Converters

R Debnath, GS Gupta, D Kumar - Renewable Resources and …, 2023 - taylorfrancis.com
The preordained time delay in digital controlled power electronic converters has a
substantial impact on the overall system's stability as it will vary the phase-frequency …

Analysis on Critical Oscillations in Multi-parallel Inverter System with WAC Control

N Babu, NP Padhy - 2022 IEEE IAS Global Conference on …, 2022 - ieeexplore.ieee.org
In the grid-tied inverters with LCL type output filter, inverter-side and grid-side current control
schemes suffer from stability issues due to the control delay and filter resonance. Weighted …

Comparative Study of Grid-Following LCL-Filtered Inverters with Sampling Different Voltages

J Zhong, J Xu, S Xie - … Congress & Exposition-Asia (ECCE-Asia …, 2021 - ieeexplore.ieee.org
The grid-connected inverter is the key interface in the distributed power generation system.
To realize a high-quality grid current of the inverter, at least, the sensors for one current and …

[PDF][PDF] Grid Fault Responses of Voltage-Source Converters in Wind Turbine Applications

MG TAUL - 2019 - vbn.aau.dk
Resumé Med et globalt stigende elektrisk energiforbrug samt et ønske om en markant
reduktion i nutidens CO2 aftryk, kræves der nye løsninger i forhold til produktion og …