Suitability of active noise barriers for construction sites

S Sohrabi, T Pàmies Gómez, J Romeu Garbí - Applied sciences, 2020 - mdpi.com
Barriers are increasingly used to protect the pedestrian and neighboring buildings from
construction noise activities. This study aims to investigate the suitability of applying active …

Comparison of multimicrophone probe design and processing methods in measuring acoustic intensity

CP Wiederhold, KL Gee, JD Blotter… - The Journal of the …, 2014 - pubs.aip.org
Three multimicrophone probe arrangements used to measure acoustic intensity are the four-
microphone regular tetrahedral, the four-microphone orthogonal, and the six-microphone …

Comparison of methods for processing acoustic intensity from orthogonal multimicrophone probes

CP Wiederhold, KL Gee, JD Blotter… - The Journal of the …, 2012 - pubs.aip.org
One design for three-dimensional multimicrophone probes is the four-microphone
orthogonal design consisting of one microphone at an origin position with the other three …

Optimization of the active control of turboprop cabin noise

J Romeu, JI Palacios, A Balastegui, T Pamies - Journal of Aircraft, 2015 - arc.aiaa.org
In this paper, a modified cost function is proposed in order to achieve the maximum noise
attenuation using a set of secondary sources for a harmonically excited sound field. The …

[HTML][HTML] Verification of a near-field error sensor placement method in active control of compact noise sources

BM Shafer, KL Gee, SD Sommerfeldt - The Journal of the Acoustical …, 2010 - pubs.aip.org
Recent experiments in active noise control (ANC) have used near-field error sensors whose
locations are determined according to the minimization of sound power. Sensors should be …

A near-field error sensing strategy for compact multi-channel active sound radiation control in free field

J Tao, Q Guo, X Qiu - The Journal of the Acoustical Society of America, 2019 - pubs.aip.org
Noise reduction performance of a compact active sound radiation control system is
significantly affected by locations of the error microphones which are required to be installed …

一种针对紧凑式管道有源降噪系统的误差传感策略

陈柏村, 陶建成 - 南京大学学报(自然科学版), 2021 - jns.nju.edu.cn
The placement of secondary sources and error microphones is an important factor that
determines the noise reduction performance of an ANC (active noise control) system. This …

Optimal acoustic error sensing for global active control in a harmonically excited enclosure

J Romeu, A Balastegui, T Pamies, R Arcos - Acoustical Physics, 2014 - Springer
The performance of an active control system in global control of enclosed sound fields
depends largely on the localization of the error sensors, among other factors. In this paper a …

Active control of axial and centrifugal fan noise

SD Sommerfeldt, KL Gee - Proceedings of Meetings on Acoustics, 2013 - pubs.aip.org
Small axial and centrifugal cooling fans are routinely used with information technology (IT)
equipment to provide cooling. However, these fans also generate acoustic noise which can …

Characterization of microphone placement and noise sensitivity in a global active noise control system for a compact noise source

RL Rust, SD Sommerfeldt, KL Gee… - Noise Control …, 2013 - ingentaconnect.com
This paper presents a sensitivity analysis to error microphone placement and extraneous
noise sources for two control source configurations used for the active control of noise …