Aseptic loosening of total joint replacements: mechanisms underlying osteolysis and potential therapies

Y Abu-Amer, I Darwech, JC Clohisy - Arthritis research & therapy, 2007 - Springer
Total joint replacement, although considered an excellent surgical procedure, can be
complicated by osteolysis induced by implant particles and subsequent aseptic loosening of …

Significance of tribocorrosion in biomedical applications: overview and current status

MT Mathew, P Srinivasa Pai, R Pourzal… - Advances in …, 2009 - Wiley Online Library
Recently,“tribocorrosion,” a research area combining the science of tribology and corrosion,
has drawn attention from scientists and engineers belonging to a wide spectrum of research …

Glenoid component failure in total shoulder arthroplasty

FA Matsen III, J Clinton, J Lynch, A Bertelsen… - JBJS, 2008 - journals.lww.com
➤ The possibility of glenoid component failure should be considered whenever a total
shoulder arthroplasty has an unsatisfactory result. High-quality radiographs made in the …

Agglomeration and sedimentation of TiO2 nanoparticles in cell culture medium

ZE Allouni, MR Cimpan, PJ Høl, T Skodvin… - Colloids and surfaces B …, 2009 - Elsevier
The physicochemical characterization of nanoparticles in suspension is a prerequisite for
the adequate assessment of their potential biological effect. Little is known to date about the …

Effect of surface nanocrystallization on the corrosion behavior of Ti–6Al–4V titanium alloy

S Jelliti, C Richard, D Retraint, T Roland… - Surface and Coatings …, 2013 - Elsevier
By means of surface mechanical attrition treatment (SMAT), a nanocrystalline surface layer
was formed on a Ti–6Al–4V alloy. The corrosion behavior of Ti–6Al–4V in a Ringer's …

XPS and EIS study of the passive film formed on orthopaedic Ti–6Al–7Nb alloy in Hank's physiological solution

I Milošev, T Kosec, HH Strehblow - Electrochimica Acta, 2008 - Elsevier
The composition and structure of the passive film formed on Ti–6Al–7Nb alloy by
electrochemical oxidation in Hank's physiological solution were studied using X-ray …

Soluble and particulate Co‐Cr‐Mo alloy implant metals activate the inflammasome danger signaling pathway in human macrophages: a novel mechanism for implant …

MS Caicedo, R Desai, K McAllister… - Journal of …, 2009 - Wiley Online Library
Immune reactivity to soluble and particulate implant debris remains the primary cause of
aseptic inflammation and implant loosening. However, the intracellular mechanisms that …

Direct in vivo inflammatory cell‐induced corrosion of CoCrMo alloy orthopedic implant surfaces

JL Gilbert, S Sivan, Y Liu, SB Kocagöz… - … Research Part A, 2015 - Wiley Online Library
Abstract Cobalt–chromium–molybdenum (CoCrMo) alloy, used for over five decades in
orthopedic implants, may corrode and release wear debris into the body during use. These …

Wear debris characterization and corresponding biological response: artificial hip and knee joints

MJ Nine, D Choudhury, AC Hee, R Mootanah… - Materials, 2014 - mdpi.com
Wear debris, of deferent sizes, shapes and quantities, generated in artificial hip and knees is
largely confined to the bone and joint interface. This debris interacts with periprosthetic …

Lymphocyte proliferation responses in patients with pseudotumors following metal‐on‐metal hip resurfacing arthroplasty

YM Kwon, P Thomas, B Summer… - Journal of …, 2010 - Wiley Online Library
Locally destructive soft tissue pseudotumor has been reported in patients following metal‐on‐
metal hip resurfacing arthroplasty (MoMHRA). A delayed hypersensitivity reaction type IV to …