Time-variant service reliability of post-tensioned, segmental, concrete bridges exposed to corrosive environments

RG Pillai, MD Hueste, P Gardoni, D Trejo… - Engineering …, 2010 - Elsevier
This paper presents a framework for assessing the service reliability of post-tensioned (PT)
bridges with damaged and undamaged tendons containing voids, chlorides, and moisture …

Probabilistic capacity models for corroding posttensioning strands calibrated using laboratory results

P Gardoni, RG Pillai, MBD Hueste… - Journal of …, 2009 - ascelibrary.org
The presence of air voids, moisture, and chlorides inside tendons or ducts was cited as a
reason for the early age strand corrosion and failure in the Mid-bay, Sunshine Skyway, and …

Time-variant flexural reliability of posttensioned, segmental concrete bridges exposed to corrosive environments

RG Pillai, D Trejo, P Gardoni, MB D. Hueste… - Journal of Structural …, 2014 - ascelibrary.org
Posttensioned (PT) bridges are used on major thoroughfares because they are economical
structures for traversing long spans. Special inspections of these bridges have revealed …

Non-destructive testing methods to identify voids in external post-tensioned tendons

SB Im, S Hurlebaus - KSCE journal of civil engineering, 2012 - Springer
A considerable number of Post-Tensioned (PT) bridges have been constructed because PT
systems enable them to carry significant traffic loads and have an aesthetical structure …

Nondestructive evaluation of external post-tensioning systems to detect grout defects

T Terzioglu, MM Karthik, S Hurlebaus… - Journal of structural …, 2019 - ascelibrary.org
Management of bridge assets requires a life-cycle approach that balances design and
construction of new bridges, and maintenance of existing bridge stock. There has been a …

Probabilistic models for the tensile strength of corroding strands in posttensioned segmental concrete bridges

RG Pillai, P Gardoni, D Trejo, MBD Hueste… - Journal of materials in …, 2010 - ascelibrary.org
The presence of air voids, moisture, and chlorides inside tendon systems on segmental
posttensioned (PT) bridges has been cited as a reason for the early age corrosion and …

Inspection of voids in external tendons of posttensioned bridges

SB Im, S Hurlebaus, D Trejo - Transportation research …, 2010 - journals.sagepub.com
Segmental posttensioned bridges are major structures that carry significant traffic. Recent
investigations of these bridges identified voids in their ducts. The exposed strands at these …

[HTML][HTML] Approach to determine corrosion propensity in post-tensioned tendons with deficient grout

JC Rafols, K Lau, I Lasa, M Paredes, A ElSafty - 2013 - scirp.org
After corrosion failure of post-tensioned tendons was identified in a Florida bridge in early
2011, laboratory tests were conducted in this study on extracted sections from the failed …

[PDF][PDF] Optimum design of vertical steel tendons profile layout of post-tensioning concrete bridges: fem static analysis

AF Naser - ARPN Journal of Engineering and Applied Sciences, 2018 - academia.edu
The objectives of this study are to evaluate the optimum design of tendon profile layout, to
study the effect of tendon profile layout on the structural performance of post-tensioned …

[PDF][PDF] Repair Options for Corrosion-damaged Prestressed Concrete Structures

S Sharma, MJ Osmolska, K Hornbostel, L Bathen… - 2024 - sciendo.com
Prestressing of bridges allows construction of long spanned bridges made from thin
structural members with high flexural and shear capacity. Studies have shown that some of …