Demonstrating the use of absolute pressure sensors for monitoring stack-driven pressure differences in high-rise buildings

J Jing, S Yoon, J Joe, EJ Kim, YH Cho, JH Jo - Building and Environment, 2025 - Elsevier
As an effective alternative to differential pressure (DP) gauges, pairs of absolute (AB)
pressure sensors are always applied to monitor stack-driven pressure differences (∆ P stack) …

Analysis of vertical movement of particulate matter due to the stack effect in high-rise buildings

S Park, Y Cai, H Lim, D Song - Atmospheric Environment, 2022 - Elsevier
Outdoor particulate matters (PM) enter the indoors with airflow due to wind pressure,
temperature differences, and variable pressures from HVAC systems. PM introduced into the …

Determination of pressure difference coefficient of shuttle elevator doors in super high-rise buildings under stack effect

M Xie, J Wang - Building and Environment, 2023 - Elsevier
The stack-induced airflow of super high-rise buildings in winter results in obvious indoor
environmental problems at the shuttle elevator shaft. Strong pressure difference can cause …

Reassessing ISO 9972 constraints: A mathematical analysis of errors in building airtightness tests due to steady wind and stack effect

B Kölsch, V Leprince, A Mélois, B Moujalled - Energy and Buildings, 2024 - Elsevier
Building airtightness significantly impacts its energy use estimation. The fan pressurization
test, outlined in ISO 9972, is the most commonly used assessment method. A crucial …

Investigating the impact of stack effect on ventilation performance of residential kitchen exhaust shaft system

Y Yang, Z Wang, X Li, D Zhao, J Zuo, Y Ren, W Lyu… - Energy and …, 2023 - Elsevier
In contemporary architecture, a residential kitchen exhaust shaft is a common vertical shaft
to extract cooking fumes generated in multiple kitchens, such as may be found in tower …

An analytical model of stack ventilation in a shaft with controllable air volume

K Zheng, W Xu, A Li, C Yang, L Chen, J Li - Journal of Building Engineering, 2023 - Elsevier
This work investigates a stack ventilation system in a shaft with controllable air volume
suitable for large public buildings, which can adjust natural ventilation volume on demand …

Evaluating ventilation system retrofits for high-rise residential buildings using a CONTAM model

JP Fine, MF Touchie - Building and Environment, 2021 - Elsevier
Abstract In Canada and the United States, pressurized corridor ventilation systems are
common in older high-rise multi-unit residential buildings (MURBs). There is growing …

Field measurement and coupled simulation for the shuttle elevator shaft cooling system in super high-rise buildings

M Xie, J Wang, J Zhang, J Gao, C Pan, C Li - Building and Environment, 2021 - Elsevier
The stack effect in super high-rise buildings causes various negative problems in winter. The
shuttle elevator shafts are the main vertical movement route and also the most vulnerable …

A novel method for evaluating stack pressure in real high-rise buildings: Optimization of measurement points

JJ Jing, KH Ji, S Yoon, JH Jo - Building and Environment, 2024 - Elsevier
Excessive stack pressure in a high-rise building always causes various problems, and the
most direct way to understand the extent of the stack pressure across building components …

Optimization method on brace arrangement of center brace steel frame structural system

Y Zhu, Y Fan, J Pan, F Hu, Z Wu, Z Wang - Structural and Multidisciplinary …, 2024 - Springer
Traditional center brace steel frame structural systems typically focus on refining the member
cross-section size in the brace arrangement and optimization analysis. However, they often …