Data-driven digital twins for technical building services operation in factories: A cooling tower case study

C Blume, S Blume, S Thiede, C Herrmann - Journal of Manufacturing and …, 2020 - mdpi.com
Cyber-physical production systems (CPPS) and digital twins (DT) with a data-driven core
enable retrospective analyses of acquired data to achieve a pervasive system …

Exploring the regional characteristics of inter-provincial CO2 emissions in China: an improved fuzzy clustering analysis based on particle swarm optimization

S Yu, YM Wei, J Fan, X Zhang, K Wang - Applied energy, 2012 - Elsevier
The better to explore the regional characteristics of inter-provincial CO2 emissions and the
rational distribution of the reduction of emission intensity reduction in China, this paper …

Analysis of the effect of seasonal climate changes on cooling tower efficiency, and strategies for reducing cooling tower power consumption

RFF Pontes, WM Yamauchi, EKG Silva - Applied Thermal Engineering, 2019 - Elsevier
Cooling towers are widely used in chemical industries to cool water with ambient air that is
susceptible to weather changes not only during the day, but also during the year, resulting in …

Cooling tower management in manufacturing companies: A cyber-physical system approach

C Schulze, S Thiede, B Thiede, D Kurle… - Journal of cleaner …, 2019 - Elsevier
Cooling towers are part of industrial technical building services and one of the main drivers
for water and energy demands in industry. For planning and operation, the management of …

Artificial neural network analysis of the performance characteristics of a reversibly used cooling tower under cross flow conditions for heat pump heating system in …

J Wu, G Zhang, Q Zhang, J Zhou, Y Wang - Energy and buildings, 2011 - Elsevier
This study deals with predicting the performance characteristics of a reversibly used cooling
tower (RUCT) under cross flow conditions for heat pump heating system in winter using …

Experimental study on the thermal performance of mechanical cooling tower with rotational splash type packing

AM Lavasani, ZN Baboli, M Zamanizadeh… - Energy conversion and …, 2014 - Elsevier
This paper deals with an experimental investigation of thermal performance of a forced draft
counter flow wet cooling tower filled with a rotational splash type packing. Tower's …

Failure analysis of induced draft fan used in a thermal power plant using coordinated condition monitoring approach: A case study

HP Jagtap, AK Bewoor, R Kumar - Engineering Failure Analysis, 2020 - Elsevier
Early detection of the fault is not only essential to ensure the current health of the critical
equipment but also to diagnose the fault before any catastrophic failure. In order to improve …

[HTML][HTML] Development of a hybrid model for reliably predicting the thermal performance of direct contact countercurrent cooling towers

C Jayaweera, N Groot, S Meul, A Verliefde… - International Journal of …, 2022 - Elsevier
Cooling towers are a primary and vital component of the cooling cycle in a chemical plant.
The heat and mass transfer inside a cooling tower is governed by the complex geometry of …

Parallel hybrid model for mechanical draft counter flow wet-cooling tower

Y Guo, F Wang, M Jia, S Zhang - Applied Thermal Engineering, 2017 - Elsevier
A parallel hybrid model for mechanical draft counter flow wet-cooling tower is proposed in
this paper. The model consists of mechanistic model based on Merkel's theory and Least …

Modeling of existing cooling towers in ASPEN PLUS using an equilibrium stage method

JA Queiroz, VMS Rodrigues, HA Matos… - Energy conversion and …, 2012 - Elsevier
Simulation of cooling tower performance considering operating conditions away from design
is typically based on the geometrical parameters provided by the cooling tower vendor …