Normative findings of electrically evoked compound action potential measurements using the neural response telemetry of the Nucleus CI24M cochlear implant …

D Cafarelli Dees, N Dillier, WK Lai… - Audiology and …, 2005 - karger.com
One hundred and forty-seven adult recipients of the Nucleus® 24 cochlear implant system,
from 13 different European countries, were tested using neural response telemetry to …

Electrically evoked auditory steady state responses in cochlear implant users

M Hofmann, J Wouters - Journal of the Association for Research in …, 2010 - Springer
Auditory steady state responses are neural potentials in response to repeated auditory
stimuli. This study shows that electrically evoked auditory steady state responses (EASSRs) …

Neural response telemetry reconsidered: I. The relevance of ECAP threshold profiles and scaled profiles to cochlear implant fitting

A Botros, C Psarros - Ear and Hearing, 2010 - journals.lww.com
Objective: For more than a decade, Neural Response Telemetry (NRT™) has provided
direct access to the electrically evoked compound action potential (ECAP) as elicited by the …

Guidelines for best practice in the audiological management of adults using bimodal hearing configurations

JT Holder, MA Holcomb, H Snapp… - … & neurotology open, 2022 - journals.lww.com
Clinics are treating a growing number of patients with greater amounts of residual hearing.
These patients often benefit from a bimodal hearing configuration in which acoustic input …

Cochlear implant fitting strategies

U Hoppe, T Liebscher, J Hornung - HNO, 2017 - Springer
Zusammenfassung Bei der Cochleaimplantat (CI)-Anpassung wird der elektrische
Dynamikbereich festgelegt, der vom CI-Träger für die Wahrnehmung von Schallereignissen …

Cochlear implant upper stimulation levels: eSRT vs. loudness scaling

JT Holder, MR Henry, AE MacDonald… - Otology & …, 2023 - journals.lww.com
Cochlear Implant Upper Stimulation Levels: eSRT vs. Loudness... : Otology & Neurotology
Cochlear Implant Upper Stimulation Levels: eSRT vs. Loudness Scaling : Otology & …

Audiological outcomes and map characteristics in children with perimodiolar and slim straight array cochlear implants in opposite ears

LR Park, HFB Teagle, KD Brown, EB Gagnon… - Otology & …, 2017 - journals.lww.com
Objective: To identify differences in outcomes and map characteristics in pediatric bilateral
cochlear implants with modiolar conforming and lateral wall arrays in opposite ears. Study …

Characterization of the electrically evoked compound action potential of the vestibular nerve

K Nie, SM Bierer, L Ling, T Oxford… - Otology & …, 2011 - journals.lww.com
Objective: We recorded intraoperative and postoperative electrically evoked compound
action potentials (ECAPs) in rhesus monkeys implanted with a vestibular neurostimulator …

Comparisons of electrophysiological and psychophysical fitting methods for cochlear implants

J Müller-Deile, N Neben, N Dillier… - … Journal of Audiology, 2023 - Taylor & Francis
Objective This study compared two different versions of an electrophysiology-based
software-guided cochlear implant fitting method with a procedure employing standard …

Clinical use of a system for the automated recording and analysis of electrically evoked compound action potentials (ECAPs) in cochlear implant patients

L Gärtner, T Lenarz, G Joseph, A Büchner - Acta oto-laryngologica, 2010 - Taylor & Francis
Conclusion: The CustomSoundEP software can record ECAP traces in an automated
manner and calculate the ECAP threshold from them. These values are in good agreement …