A review of icing and anti-icing technology for transmission lines

Z Zhang, H Zhang, S Yue, W Zeng - Energies, 2023 - mdpi.com
This paper reviews the application of various advanced anti-icing and de-icing technologies
in transmission lines. Introduces the influence of snowing and icing disasters on …

AC failure voltage of iced and contaminated composite insulators in different natural environments

X Qiao, Z Zhang, X Jiang, R Sundararajan… - International Journal of …, 2020 - Elsevier
It is found that some composite insulators with faults in transmission lines have no defect
when they are tested in the laboratory, so there is a certain difference between the …

冰灾对输电线故障率影响的时空评估

谢云云, 薛禹胜, 文福拴, 董朝阳, 赵俊华 - 电力系统自动化, 2013 - epjournal.csee.org.cn
将冰灾造成停电灾难的问题解耦为: 从冰雪到冻雨, 从冻雨到覆冰, 从覆冰到电网故障,
从相继故障到大停电的过程. 冻雨影响输电线故障率的途径涉及冻雨形成的气象规律; …

Insulator flashover under icing conditions

M Farzaneh - IEEE Transactions on Dielectrics and Electrical …, 2014 - ieeexplore.ieee.org
Atmospheric ice accretion, combined with pollution, has been recognized as a significant
risk factor in the reliability of line and station insulators in cold climate regions. Flashovers …

Unraveling the “U-shaped” dependence of surface flashover performance on the surface trap level

S Li, Z Li, Y Huang, H Xu, F Aslam, D Min… - IEEE Access, 2019 - ieeexplore.ieee.org
The effects of surface traps on surface flashover remain controversial. To clarify the relation
between surface flashover and surface trap level, in this work, the surface trap level of epoxy …

Growth characteristics and influence analysis of insulator strings in natural icing

Z Zhang, H Zhang, S Yue, X Zhang, C Li… - Electric Power Systems …, 2024 - Elsevier
Icing flashover of insulator strings has always been a serious factor threatening the safety
and stability of the power grid. Researchers have simulated icing based on an artificial …

50 years in icing performance of outdoor insulators

M Farzaneh, WA Chisholm - IEEE Electrical Insulation …, 2014 - ieeexplore.ieee.org
During the last 50 years a significant technical advance, namely in our understanding and
control of switching-surge overvoltages, has had some unintended and adverse …

Icing flashover characteristics and discharge process of 500 kV AC transmission line suspension insulator strings

Y Liu, S Gao, D Huang, T Yao, X Wu… - IEEE Transactions on …, 2010 - ieeexplore.ieee.org
The icing flashover characteristics and discharge processes of 500 kV ac transmission line
long insulator strings energized in the ice accretion were studied. The influence of pollution …

Electric Field Distribution and AC Breakdown Characteristics of Polluted Novel Lightning Protection Insulator under Icing Conditions

J Lu, J Hu, Z Fang, X Qiao, Z Zhang - Energies, 2021 - mdpi.com
As a result of lightning strikes, pollution, and ice, overhead distribution wires might be short-
circuited and trip. As a result, researchers have developed a new lightning protection …

Effect of grading ring on ice characteristics and flashover performance of 220 kVcomposite insulators with different shed configurations

L Shu, S Wang, X Jiang, Q Hu, X Yang… - … on Dielectrics and …, 2015 - ieeexplore.ieee.org
The energized icing tests for five kinds of 220 kV composite insulators with and without the
grading ring (GR) at the high voltage (HV) end are performed in the artificial climate …