A method for accurate parameter estimation of series compensated transmission lines using synchronized data

S Gajare, AK Pradhan, V Terzija - IEEE Transactions on Power …, 2017 - ieeexplore.ieee.org
Power system software used for analysis and dynamic simulation and relay settings require
accurate model parameters of different elements for precise results. For this, transmission …

Fault location in series capacitor compensated three-terminal transmission lines based on the analysis of voltage and current phasor equations and asynchronous …

A Saffarian, M Abasi - Electric Power Systems Research, 2020 - Elsevier
In this study, a new algorithm for fault location in series capacitor compensated three-
terminal transmission lines using the distributed line model is proposed. The proposed …

Improved first zone reach setting of artificial neural network‐based directional relay for protection of double circuit transmission lines

A Yadav, A Swetapadma - IET Generation, Transmission & …, 2014 - Wiley Online Library
This study proposes an artificial neural network‐based protection scheme for double circuit
transmission line with improved first zone reach setting up to 99% of line length. The …

Fault detection in wind farm integrated series capacitor compensated transmission line using Hilbert Huang transform

N Sharma, S Ali, G Kapoor - 2018 International Conference on …, 2018 - ieeexplore.ieee.org
In this paper, a fault detection and faulty phase identification technique is proposed for the
protection of series capacitor compensated three phase transmission line connected with …

Single-phase-to-ground fault protection based on zero-sequence current ratio coefficient for low-resistance grounding distribution network

J Li, Y Li, Y Wang, J Song - Global Energy Interconnection, 2021 - Elsevier
Definite-time zero-sequence over-current protection is presently used in systems whose
neutral point is grounded by a low resistance (low-resistance grounding systems). These …

Adaptive distance relaying scheme in series compensated transmission lines

SG Srivani, KP Vittal - … on Power Electronics, Drives and Energy …, 2010 - ieeexplore.ieee.org
The introduction of the capacitance in series with the line reactance adds certain
complexities to the effective application of impedance based distance relays. The paper …

[HTML][HTML] Time domain complete protection scheme for parallel transmission lines

A Swetapadma, A Yadav - Ain Shams Engineering Journal, 2016 - Elsevier
In this paper, time domain relaying schemes for complete protection of parallel transmission
lines using wavelet and artificial neural network (ANN) are presented. Four different ANN …

Distance Relaying algorithm for a single line-to-ground fault on single infeed transmission lines

VH Makwana, BR Bhalja, VH Makwana… - … Line Protection Using …, 2016 - Springer
The work presented in this chapter addresses the problems encountered by the
conventional digital distance relay used for the protection of transmission lines fed from one …

A new intelligent method for parallel transmission lines protection

AH Azimi, AA Abdoos - Technology and Economics of Smart Grids and …, 2020 - Springer
In many countries, the parallel lines are widely used in transmission systems due to
economic and technical benefits. Distance relays have poor performance on the protection …

A fuzzy ARTMAP based high impedance arc fault detection scheme

SMA Saleem, AM Sharaf - 2008 Canadian Conference on …, 2008 - ieeexplore.ieee.org
This paper presents the application of fuzzy ARTMAP to investigate a long outstanding
problem of arc type fault detection in electric systems, distribution systems, process …