| Crevice Corrosion

M Iannuzzi, E Hornus, M Salasi - 2022 - asmedigitalcollection.asme.org
Crevice corrosion affects most metals and alloys and is among the most damaging forms of
corrosion. Crevice geometries can be found on a wide range of structures and components …

Electrochemical Studies of Open-Circuit Potential Drift of Carbon Steel in Nuclear Waste Simulants

S Chawla, K Evans, KM Sherer, JA Beavers… - NACE …, 2017 - onepetro.org
Nuclear wastes are stored in large, underground carbon-steel storage tanks at the Hanford
site. Most of the liquid wastes are highly alkaline in nature, typically with pH values between …

Pitting Factor Criteria for localized corrosion inhibition of liquid radioactive waste stored in Hanford double shell tanks

RE Fuentes, BJ Wiersma, CL Girardot, TJ Venetz… - NACE …, 2019 - onepetro.org
Liquid radioactive waste stored in carbon steel double shell tanks (DSTs) at Hanford has a
comprehensive chemistry control program to prevent general corrosion, stress corrosion …

The Passive Film Evolution of Carbon Steel in Hanford Waste Simulants

KJ Evans, S Chawla, KM Sherer, JA Beavers… - NACE …, 2018 - onepetro.org
Nuclear wastes are stored in large, underground carbon steel storage tanks at the Hanford
site. Most of the liquid wastes are highly alkaline, typically with pH values between 12 and …

[PDF][PDF] Hanford double shell waste tank corrosion studies–final report Fy2015

RE Fuentes, RB Wyrwas - … Laboratory, Aiken, South Carolina, SRNL-STI …, 2016 - sti.srs.gov
EXECUTIVE SUMMARY For FY18, Savannah River National Laboratory (SRNL) focused on
four main tasks in its study of corrosion of Hanford Double-Shell Tanks (DSTs). The New …

Analysis of Pitting Susceptibility of Low Carbon Steels for the Refinement of Salt Dissolution Inhibitor Requirements

JT Boerstler, BJ Wiersma, KB Martin… - AMPP CORROSION, 2023 - onepetro.org
Corrosion control limits for High-Level Waste storage are being revisited to determine if a
ratio of inhibiting and aggressive species, the Pitting Factor, is applicable to predicting …

Analysis of the Pitting Factor for Predicting Localized Corrosion of Liquid Radioactive Waste at Elevated Temperatures

RE Fuentes, BJ Wiersma, CL Girardot… - NACE CORROSION, 2021 - onepetro.org
Millions of liters of liquid radioactive waste are stored in double shell tanks (DSTs) at
Hanford Site. The DSTs were constructed of carbon steel from 1968 to 1986 and have a …

Refinement of Salt Dissolution Inhibitor Requirements (Interim Report)

JT Boerstler - 2021 - osti.gov
At Savannah River Site, High-Level Waste is stored in below-grade carbon steel tanks. This
waste in part consists of sludge, salt cake, and/or supernate. Preparation of this waste for …

Crack Growth Rate Testing to Evaluate SCC Susceptibility of a High Level Nuclear Waste Tank at Hanford: Life Cycle Tests

BC Rollins, S Chawla, KM Sherer, J Gerst… - NACE …, 2019 - onepetro.org
Stress corrosion cracking (SCC) is a documented threat to the integrity of the radioactive
waste storage tanks at Hanford. An extensive amount of time and effort has been spent …

Laboratory Investigation of Corrosion of Type 304L Stainless Steel in Hanford Direct-Feed Low-Activity Waste Effluents

S Chawla, K Evans, B Rollins, K Sherer… - NACE …, 2018 - onepetro.org
This paper presents the results of a laboratory investigation performed to evaluate the
impact of key Hanford tank waste chemical constituents on corrosion of Type 304L stainless …