Fault current limiters in power systems: A comprehensive review

MS Alam, MAY Abido, I El-Amin - Energies, 2018 - mdpi.com
Power systems are becoming more and more complex in nature due to the integration of
several power electronic devices. Protection of such systems and augmentation of reliability …

柔性直流配电系统故障分析及限流方法

李斌, 何佳伟 - 中国电机工程学报, 2015 - epjournal.csee.org.cn
直流配电系统的故障隔离是保障直流系统供电可靠性的关键技术. 分析直流配电系统直流故障时
的暂态特性, 指出故障持续过程中直流电容放电, 续流二极管自然换向导通和二极管同时导通三 …

[图书][B] Wind energy systems: solutions for power quality and stabilization

MH Ali - 2012 - books.google.com
Unlike conventional power plants, wind plants emit no air pollutants or greenhouse gases—
and wind energy is a free, renewable resource. However, the induction machines commonly …

Integration of fault current limiters in electric power systems: A review

S Ouali, A Cherkaoui - IEEE Systems Journal, 2020 - ieeexplore.ieee.org
Fault current limiters (FCLs) are promising fault current management measures and one of
the most economical solutions to today's electric power systems challenges that could have …

Optimal location and sizing of fault current limiters in mesh networks using iterative mixed integer nonlinear programming

P Yu, B Venkatesh, A Yazdani… - IEEE Transactions on …, 2016 - ieeexplore.ieee.org
In some mature power systems located in densely populated areas, an increase in demand
and supply is resulting in very high short-circuit levels that are either too close to or over the …

A novel approach to determine the optimal location of SFCL in electric power grid to improve power system stability

G Didier, J Leveque, A Rezzoug - IEEE Transactions on Power …, 2012 - ieeexplore.ieee.org
This paper presents a novel approach to determine the optimal location of a resistive
superconducting fault current limiter (SFCL) for enhancing the transient stability of an electric …

Optimal placement of superconducting fault current limiters (SFCLs) for protection of an electric power system with distributed generations (DGs)

HC Jo, SK Joo, K Lee - IEEE Transactions on Applied …, 2012 - ieeexplore.ieee.org
Power flow patterns and fault current levels are influenced by the introduction of distributed
generations (DGs) in an electric power system. In particular, the change in the fault current …

Optimal allocation of HTS-FCL for power system security and stability enhancement

S Alaraifi, MS El Moursi… - IEEE Transactions on …, 2013 - ieeexplore.ieee.org
This paper presents a new problem formulation for allocation of high-temperature
superconducting fault current limiter (HTS-FCL) in power systems for security and stability …

The effect of SFCL on electric power grid with wind-turbine generation system

WJ Park, BC Sung, JW Park - IEEE Transactions on Applied …, 2010 - ieeexplore.ieee.org
This paper describes the study to analyse the effect of the superconducting fault current
limiter (SFCL) on an electric power grid with the wind-turbine generation, which is a …

Effect of a SFCL on commutation failure in a HVDC system

HJ Lee, GT Son, JI Yoo, JW Park - IEEE transactions on …, 2012 - ieeexplore.ieee.org
This paper describes an analysis of the effects of a superconducting fault current limiter
(SFCL) on commutation failure in a high-voltage direct current (HVDC) system. Most …