Smart wound dressings for diabetic chronic wounds

E Gianino, C Miller, J Gilmore - Bioengineering, 2018 - mdpi.com
Given their severity and non-healing nature, diabetic chronic wounds are a significant
concern to the 30.3 million Americans diagnosed with diabetes mellitus (2015). Peripheral …

A study on pressure ulcer: influencing factors and diagnostic techniques

GA Nancy, R Kalpana… - The International Journal …, 2022 - journals.sagepub.com
Pressure ulcer (PU) is one of the most common occurrences in bedridden subjects. Despite
the standard of care, there is a huge challenge in monitoring immobile subjects in all the …

A matrix metalloproteinase sensing biosensor for the evaluation of chronic wounds

SM Kang, H Cho, D Jeon, SH Park, DS Shin, CY Heo - BioChip Journal, 2019 - Springer
The increasing prevalence of the elderly in global society is being accompanied by rapidly
increasing numbers of patients with cerebrovascular disease or diabetes, and patients with …

Feasibility study of early pressure ulcer detection using electrical impedance tomography

S Liu, Y Xu, S Chen, Q Hu… - IEEE Transactions on …, 2023 - ieeexplore.ieee.org
Pressure ulcers are chronic skin wounds with a particularly high morbidity and a relatively
low recovery rate. At present, there is still a lack of a portable and visual real-time monitoring …

Nfcapsule: An ingestible sensor pill for eosinophilic esophagitis detection based on near-field coupling

J Zhang, G Balakrishnan, S Srinidhi, A Bhat… - Proceedings of the 20th …, 2022 - dl.acm.org
This paper presents NFCapsule, a light-weight, battery-free, and ingestible biomedical
sensor that can potentially enable non-invasive detection of active eosinophilic esophagitis …

Development of an electrical impedance tomography spectroscopy for pressure ulcer monitoring tool: preliminary study

SI Kang, S Noyori, H Noguchi… - 2020 42nd Annual …, 2020 - ieeexplore.ieee.org
This study developed a sensor system that measures electrical impedance with a
surrounding electrode array that is located around the wound and estimates the depth and …

Long term monitoring of a pressure ulcer risk patient using thermal images

SL Bennett, R Goubran… - 2017 39th Annual …, 2017 - ieeexplore.ieee.org
Patients in an immobile state are susceptible to pressure ulcers, which are localized injuries
to the skin and/or underlying tissues due to prolonged pressure. This paper builds upon a …

Detecting and monitoring periprosthetic joint infection by using electrical bioimpedance spectroscopy: a preliminary case study

M Balato, C Petrarca, P Arpaia, N Moccaldi, F Mancino… - Diagnostics, 2022 - mdpi.com
A method to detect the presence of infection after Total Joint Arthroplasty is presented. The
method is based on Electrical Bioimpedance Spectroscopy and guarantees low latency, non …

Bioimpedance sensor array for monitoring chronic wounds: Validation of method feasibility

M Antoszewska, P Spychalski… - International Wound …, 2024 - Wiley Online Library
In an ageing society, the incidence of hard‐to‐heal wounds is rising. Chronic wound healing
is a complex process, which requires specialised treatment. Clinical assessment of the …

Imprinting RF Backscatter on Flexible Surfaces for Next-Generation Sensing

J Zhang - 2024 - search.proquest.com
In this dissertation, we design radio-frequency (RF) backscatter platforms on flexible
surfaces to enable next-generation sensing applications. In a typical RF backscatter system …