Accuracy of cuff-measured blood pressure: systematic reviews and meta-analyses

DS Picone, MG Schultz, P Otahal, S Aakhus… - Journal of the American …, 2017 - jacc.org
Background: Hypertension (HTN) is the single greatest cardiovascular risk factor worldwide.
HTN management is usually guided by brachial cuff blood pressure (BP), but questions …

Non-invasive estimation of aortic blood pressures: a close look at current devices and methods

S Millasseau, D Agnoletti - Current pharmaceutical design, 2015 - ingentaconnect.com
While for years clinicians have used cuff pressure to assess patients' cardiovascular risk,
recent evidences has shown that aortic pressure, or more specifically aortic systolic and …

Evaluation of the Vicorder, a novel cuff-based device for the noninvasive estimation of central blood pressure

G Pucci, J Cheriyan, A Hubsch, SS Hickson… - Journal of …, 2013 - journals.lww.com
Objectives: The Vicorder is a new brachial cuff-based device that estimates central blood
pressure (cBP) using a brachial-to-aortic transfer function. The aim of this study was to …

Clinical assessment of central blood pressure

H Miyashita - Current hypertension reviews, 2012 - ingentaconnect.com
Central aortic blood pressure (CBP) is increasingly considered a better cardiovascular
prognostic marker than conventional cuff brachial blood pressure. Because CBP cannot be …

Brachial and radial systolic blood pressure are not the same: evidence to support the Popeye phenomenon

MK Armstrong, MG Schultz, DS Picone, JA Black… - …, 2019 - Am Heart Assoc
Radial intra-arterial blood pressure (BP) is sometimes used as the reference standard for
validation of brachial cuff BP devices. Moreover, there is an emerging wearables market …

Transfer function-derived central pressure and cardiovascular disease events: the Framingham Heart Study

GF Mitchell, SJ Hwang, MG Larson… - Journal of …, 2016 - journals.lww.com
Background: Relations between central pulse pressure (PP) or pressure amplification and
major cardiovascular disease (CVD) events are controversial. Estimates of central aortic …

Central pressure should not be used in clinical practice

GF Mitchell - Artery research, 2015 - Elsevier
The heart, brain and kidneys are key targets of pulsatile damage in older people and in
patients with longstanding hypertension. These central organs are exposed to central …

Brachial-to-radial SBP amplification: implications of age and estimated central blood pressure from radial tonometry

DS Picone, RED Climie, KDK Ahuja… - Journal of …, 2015 - journals.lww.com
Objectives: The reference standard for noninvasive estimation of central blood pressure (BP)
is radial tonometry calibrated using brachial SBP and DBP. Brachial-to-radial-SBP …

[HTML][HTML] New method to estimate central systolic blood pressure from peripheral pressure: a proof of concept and validation study

D Chemla, S Millasseau, O Hamzaoui… - Frontiers in …, 2021 - frontiersin.org
Objective: The non-invasive estimation of central systolic blood pressure (cSBP) is
increasingly performed using new devices based on various pulse acquisition techniques …

Estimating central systolic blood pressure during oscillometric determination of blood pressure: proof of concept and validation by comparison with intra-aortic …

SE Brett, A Guilcher, B Clapp… - Blood pressure …, 2012 - journals.lww.com
Objectives Central systolic blood pressure is usually estimated by transformation of a
peripheral arterial waveform obtained by tonometry and calibrated from conventional …