Evaluation of measurement uncertainty of HMP155A humidity sensor based on correlation analysis of input quantities

M Wei, C Wen, C Li - Journal of Physics: Conference Series, 2022 - iopscience.iop.org
In view of the current situation that when the humidity sensor used GUM to evaluate the
measurement uncertainty, the correlation between the input quantities was not analyzed. We …

Uncertainly analysis of two types of humidity sensors by a humidity generator with a divided-flow system

LH Chen, C Chen - Sensors, 2018 - mdpi.com
Humidity measurement is an important technique for the agricultural, foods,
pharmaceuticals, and chemical industries. For the sake of convenience, electrical relative …

[HTML][HTML] SASO-NMCC's two pressure humidity generator: Performance characterization and reference calibration for traceable highly accurate humidity measurements

E AlSbaiy, M AlOtaibi, A AlRushud, H AlOtaibi… - Measurement …, 2025 - Elsevier
A stream of saturated gas with known water vapor content can be used in a number of ways
to create humidity references. The most popular method for implementing temperature and …

Evaluation of Humidity Sensor Calibration Uncertainty by Monte Carlo Method

M Wei, C Wen, C Li, J Miao - MAPAN, 2024 - Springer
To effectively solve the problem that the measurement uncertainty evaluation result is not
accurate and the calculation is complicated when the humidity measuring instrument is …

[HTML][HTML] Revisión del cálculo de poder calorífico y punto de rocío del gas natural, y de la estimación de sus incertidumbres

E Ayala Blanco, AA Aparicio Ariza, CE García Sánchez - Revista Ion, 2016 - scielo.org.co
El gas natural debe cumplir ciertos requisitos que garanticen que su producción, transporte,
distribución y consumo se realiza de forma segura. Estos requisitos corresponden a los …

Estimation of Psychrometer Calibration Uncertainty by Monte Carlo Method

AS Tistomo, A Achmadi, L Khairiyati… - … and Automation (ICA …, 2023 - ieeexplore.ieee.org
Propagation of distribution utilizing Monte Carlo Method (MCM) has been implemented to
estimate the psychrometer calibration uncertainty. This study is based on the calibration …

[HTML][HTML] Research on Consistency Judgement of Indication Error for Calibration Result of Humidity Sensor in Meteorology

M Wei, F Li, J Miao - Atmospheric and Climate Sciences, 2021 - scirp.org
In order to solve the lack of relevant evaluation research on the accuracy of HMP155A
humidity sensor calibration results in the past, this paper designs the corresponding …

Analysis and application on sensitivity factors of cross validation of fill rate of CPR1000 unit reactor core coolant monitoring system

Y Chen, Y Xie, Z Wang, Z Luan, J Ling - Annals of Nuclear Energy, 2019 - Elsevier
The coolant fill rate setting of CPR1000 unit reactor core has train A/B of redundancy
measuring channels, whose function is to monitor the water inventory of reactor core under …

[PDF][PDF] Giải pháp quản lý, giám sát hoạt động kiểm định, hiệu chuẩn phương tiện đo khí tượng thủy văn

ĐH Dương, NT Giang, NT Hân, TV Duẩn, N Thị, T Nga - scholar.dlu.edu.vn
Hệ thống kiểm định, hiệu chuẩn các phương tiện đo khí tượng thủy văn (KTTV) có vai trò rất
to lớn trong hoạt động lường, đảm bảo số liệu đo đạc chính xác hơn, phục vụ công tác …

[PDF][PDF] Revisión del cálculo de poder calorífico y punto de rocío del gas natural, y de la estimación de sus incertidumbres Review of calculation of calorific value and …

EA Blanco, AAA Ariza, CEG Sánchez - revistas.uis.edu.co
El gas natural debe cumplir ciertos requisitos que garanticen que su producción, transporte,
distribución y consumo se realiza de forma segura. Estos requisitos corresponden a los …