Optimized plane wave imaging for fast and high-quality ultrasound imaging

J Jensen, MB Stuart, JA Jensen - IEEE transactions on …, 2016 - ieeexplore.ieee.org
This paper presents a method for optimizing parameters affecting the image quality in plane
wave imaging. More specifically, the number of emissions and steering angles is optimized …

3-D vector flow estimation with row–column-addressed arrays

S Holbek, TL Christiansen, MB Stuart… - IEEE transactions on …, 2016 - ieeexplore.ieee.org
Simulation and experimental results from 3-D vector flow estimations for a 62+ 62 2-D row-
column (RC) array with integrated apodization are presented. A method for implementing a …

Imaging performance for two row–column arrays

H Bouzari, M Engholm, SI Nikolov… - IEEE transactions on …, 2019 - ieeexplore.ieee.org
This study evaluates the volumetric imaging performance of two prototyped 62+ 62 row-
column-addressed (RCA) 2-D array transducer probes using three synthetic aperture …

Ultrasonic 3-D Vector Flow Method for Quantitative In Vivo Peak Velocity and Flow Rate Estimation

S Holbek, C Ewertsen, H Bouzari… - IEEE Transactions …, 2016 - ieeexplore.ieee.org
Current clinical ultrasound (US) systems are limited to show blood flow movement in either 1-
D or 2-D. In this paper, a method for estimating 3-D vector velocities in a plane using the …

Individual transducer impulse response characterization method to improve image quality of array-based handheld optoacoustic tomography

KB Chowdhury, M Bader, C Dehner, D Jüstel… - Optics Letters, 2021 - opg.optica.org
The physical properties of each transducer element play a vital role in the quality of images
generated in optoacoustic (photoacoustic) tomography using transducer arrays. Thorough …

Fast plane wave 2-D vector flow imaging using transverse oscillation and directional beamforming

J Jensen, CAV Hoyos, MB Stuart… - IEEE transactions on …, 2017 - ieeexplore.ieee.org
Several techniques can estimate the 2-D velocity vector in ultrasound. Directional
beamforming (DB) estimates blood flow velocities with a higher precision and accuracy than …

Resolving ultrasound contrast microbubbles using minimum variance beamforming

K Diamantis, T Anderson, MB Butler… - IEEE transactions on …, 2018 - ieeexplore.ieee.org
Minimum Variance (MV) beamforming is known to improve the lateral resolution of
ultrasound images and enhance the separation of isolated point scatterers. This paper aims …

Quantifying image quality improvement using elevated acoustic output in B-mode harmonic imaging

Y Deng, ML Palmeri, NC Rouze, GE Trahey… - Ultrasound in medicine …, 2017 - Elsevier
Tissue harmonic imaging has been widely used in abdominal imaging because of its
significant reduction in acoustic noise compared with fundamental imaging. However, tissue …

Accurate angle estimator for high-frame-rate 2-D vector flow imaging

CAV Hoyos, MB Stuart, KL Hansen… - IEEE transactions on …, 2016 - ieeexplore.ieee.org
This paper presents a novel approach for estimating 2-D flow angles using a high-frame-rate
ultrasound method. The angle estimator features high accuracy and low standard deviation …

Optimum speckle tracking based on ultrafast ultrasound for improving blood flow velocimetry

B He, Y Zhang, K Zhang, J Chen… - IEEE transactions on …, 2020 - ieeexplore.ieee.org
Speckle tracking using optimum comparison frames (STO) is proposed to improve the blood
flow velocity profile (BFVP) estimation based on ultrafast ultrasound with coherent plane …