Operative treatment of acute distal femur fractures: systematic review of 2 comparative studies and 45 case series (1989 to 2005)

M Zlowodzki, M Bhandari, DJ Marek… - … of orthopaedic trauma, 2006 - journals.lww.com
Background The incidence of distal femur fractures is approximately 37 per 100,000 person-
years. 1 Typically, distal femur fractures are caused by a high-energy injury mechanism in …

Retrograde nailing versus fixed‐angle blade plating for supracondylar femoral fractures: a randomized controlled trial

NL Hartin, I Harris, K Hazratwala - ANZ journal of surgery, 2006 - Wiley Online Library
Background: A variety of devices have been used in the treatment of supracondylar femoral
fractures. The condylar blade plate relies on the principles of open reduction, absolute …

Internal fixation of type-C distal femoral fractures in osteoporotic bone

D Wähnert, KL Hoffmeier, G von Oldenburg, R Fröber… - JBJS, 2010 - journals.lww.com
Background: Fixation of distal femoral fractures remains a challenge, especially in
osteoporotic bone. This study was performed to investigate the biomechanical stability of …

Fractures of the distal femur: current trends in evaluation and management

RP Mashru, EA Perez - Current Opinion in Orthopaedics, 2007 - journals.lww.com
Purpose of review: The evaluation and management of distal femur fractures have
undergone a recent revolution. Traditionally, these injuries were managed with fixed angle …

Failure analysis in 316L stainless steel supracondylar blade plate

L Guerra-Fuentes, E Garcia-Sanchez… - Engineering Failure …, 2015 - Elsevier
A 316L stainless steel blade plate implant used for fixation of a femoral fracture in a female
patient failed catastrophically at four months of service. The failure examination included …

[PDF][PDF] Fixation of distal femoral fractures: Restoration of the knee motion

EI Massoud - Ulus Travma Acil Cerrahi Derg, 2015 - jag.journalagent.com
ABSTRACT BACKGROUND: Most of healed lower femoral fractures resulted in various
degree of loss of the knee motion. Flexion deficit is a serious problem for the Eastern …

[HTML][HTML] Results of Locking Compression Plate fixation in Distal Femur Fractures: A Prospective Study

B Borthakur, B Hanse, R Haque, S Jindal… - J Med …, 2016 - journalmedicalthesis.com
Background: Distal femoral fractures represents a challenging problem in orthopaedic
practice. Open reduction with Internal fixation replaces previous trend of closed conservative …

Experience of the T2 supracondylar nail in distal femoral fractures

A Ghandour, TDA Cosker, SS Kadambande, I Pallister… - Injury, 2006 - injuryjournal.com
Experience of the T2 supracondylar nail in distal femoral fractures - Injury Skip to Main Content
Skip to Main Menu Advertisement Injury Submit Log in Register Log in Submit Log in Subscribe …

Supracondylar femur nonunion associated with previous vascular repair: importance of vascular exam in preoperative planning of nonunion repair

ML Graves, JE Ryan, JW Mast - Journal of orthopaedic trauma, 2005 - journals.lww.com
One case of a Gustilo type 3C open OTA 33A-1 supracondylar femur fracture with superficial
femoral artery injury that underwent reverse saphenous vein graft repair and open reduction …

[引用][C] 股骨远端骨折的分型和治疗

许伟华, 杨述华, 杜靖远, 肖宝钧, 李进, 杨操 - 中华创伤杂志, 2005