Towards the application of electrokinetic remediation for nuclear site decommissioning

JM Purkis, PE Warwick, J Graham, SD Hemming… - Journal of Hazardous …, 2021 - Elsevier
Contamination encountered on nuclear sites includes radionuclides as well as a range of
non-radioactive co-contaminants, often in low-permeability substrates such as concretes or …

A Zoonotic Genotype of Enterocytozoon bieneusi in Horses

M Santín, JA Cortés Vecino… - Journal of …, 2010 - meridian.allenpress.com
This is the first report of Enterocytozoon bieneusi in an equid species. Feces from 195
horses from 4 locations in Colombia were examined for E. bieneusi by polymerase chain …

Managing Our Aging Physical Systems: A Corrosion Perspective

N Sridhar - Corrosion, 2024 - meridian.allenpress.com
Modern society relies heavily on complex, intertwined, physical infrastructures for their
smooth functioning. Aging of the materials in the physical infrastructures is not necessarily …

Long-Term Performance of Reference Electrodes in Alkaline Radioactive Waste Storage Environments

S Chawla, K Evans, S Feng, N Sridhar - Corrosion, 2024 - meridian.allenpress.com
Accurate measurements of corrosion potential are important for assessing the likelihood of
internal localized corrosion and stress corrosion cracking of carbon steel tanks used for …

Investigating the effective resistivity of reinforced concrete waste storage tanks at the Hanford Site

A Haas, DF Rucker, MT Levitt - Geophysics, 2022 - library.seg.org
Industrialized sites pose challenges for conducting electrical resistivity geophysical surveys
because the sites typically contain metallic infrastructure that can mask electrolytic-based …

Laboratory Studies Related to External Corrosion of Hanford's Double-Shell Tanks in Contact with Concrete Liner

KJ Evans, S Chawla, KM Sherer, BC Rollins… - NACE …, 2021 - onepetro.org
Radioactive and chemically hazardous wastes are stored at the Hanford site in underground
double-shell tanks (DSTs) constructed of carbon steel. The corrosion management of these …

Erosion and Corrosion Assessment of Type 304L Stainless Steel Jumper Removed from Nuclear Waste Transfer Service

SX Feng, JS Page - AMPP CORROSION, 2024 - onepetro.org
ABSTRACT A pipe connection assembly (jumper), fabricated from Type 304L stainless steel,
was used to transfer nuclear waste from one tank to other tanks on the Hanford Site. After …

Performing Corrosion Risks Assessments of Nuclear Waste Process Tanks Containing Variable Waste Chemistries

JS Page, ST Campbell, CL Girardot, JR Gunter - AMPP CORROSION, 2023 - onepetro.org
Legacy nuclear process waste is stored in 1,000 kgal (3,780 kL) capacity, underground,
carbon steel, double-shell tanks on the Hanford Site. Many of these tanks contain a …

Evaluation of Pitting Penetration Associated with Steel Exterior of Hanford Tanks

KJ Evans, S Chawla, KM Sherer, BC Rollins… - AMPP …, 2022 - onepetro.org
Radioactive and chemically hazardous wastes are stored at the Hanford site in underground
double-shell tanks (DSTs) constructed of carbon steel. The corrosion management of these …

Crack Growth Rate Testing to Evaluate SCC Susceptibility of a High Level Nuclear Waste Tank at Hanford: Life Cycle Tests

BC Rollins, S Chawla, KM Sherer, J Gerst… - NACE …, 2019 - onepetro.org
Stress corrosion cracking (SCC) is a documented threat to the integrity of the radioactive
waste storage tanks at Hanford. An extensive amount of time and effort has been spent …