Thermal performance behavior of a domestic hot water solar storage tank during consumption operation

AA Dehghan, A Barzegar - Energy Conversion and Management, 2011 - Elsevier
Transient thermal performance behavior of a vertical storage tank of a domestic solar water
heating system with a mantle heat exchanger has been investigated numerically in the …

Thermal performance of a full-scale stratified chilled-water thermal storage tank

WP Bahnfleth, A Musser - ASHRAE transactions, 1998 - search.proquest.com
The thermal performance of a full-scale 1.47 million gallon (5300 m^ sup 3^), 44.5 ft (13.6 m)
water-depth, naturally stratified chilled-water thermal storage tank with radial diffusers is …

Thermal performance of a vertical solar hot water storage tank with a mantle heat exchanger depending on the discharging operation parameters

M Arslan, AA Igci - Solar Energy, 2015 - Elsevier
This study presents the numerical investigations to predict the influence of the operating
parameters during discharging/consumption mode on the thermal performance of a new …

Effect of inlet design on the performance of storage-type domestic electrical water heaters

AA Hegazy - Applied Energy, 2007 - Elsevier
The effect of inlet design on the performance of storage-type domestic electrical water
heaters (EWHs) was experimentally investigated for energy conservation. Three different …

Dynamic modeling and evaluation of solid oxide fuel cell–combined heat and power system operating strategies

K Nanaeda, F Mueller, J Brouwer… - Journal of Power Sources, 2010 - Elsevier
Operating strategies of solid oxide fuel cell (SOFC) combined heat and power (CHP)
systems are developed and evaluated from a utility, and end-user perspective using a fully …

Evolution of temperature distributions in a full-scale stratified chilled-water storage tank with radial diffusers

A Musser, WP Bahnfleth - Ashrae Transactions, 1998 - search.proquest.com
Temperature profiles in a full-scale, naturally stratified, chilled-water thermal storage tank
are described. Tests were performed using a 1.4 million gallon (5,300 m3), 44.5 ft (13.56 m) …

Performance of an improved design for storage-type domestic electrical water-heaters

AA Hegazy, MR Diab - Applied Energy, 2002 - Elsevier
Performance of an improved design for storage-type domestic electrical water-heaters
(EWHs) was experimentally investigated for energy conservation. The results were …

Measured and modeled charging of a stratified chilled water thermal storage tank with slotted pipe diffusers

WP Bahnfleth, J Song, JM Cimbala - HVAC&R Research, 2003 - Taylor & Francis
As part of ASHRAE Research Project 1185, field data from the constant flow rate charging of
a stratified chilled water storage tank with double-ring octagonal slotted-pipe diffusers …

Model of the transient stratified flow into a chilled-water storage tank

KO Homan, SL Soo - International journal of heat and mass transfer, 1997 - Elsevier
This paper presents numerical solutions for the flowfield transients with a single jet of cold
liquid entering horizontally at the bottom of a tall tank initially filled with hotter liquid which is …

Field-measured performance of four full-scale cylindrical stratified chilled-water thermal storage tanks

A Musser, WP Bahnfleth - ASHRAE Transactions, 1999 - search.proquest.com
Results are presented for controlled flow rate tests in four full-scale cylindrical chilled-water
storage tanks. The tanks range in volume from 1.15 to 5.18 million gallons (4.35 to 19.61 …