2015 Atomic Spectrometry Update–a review of advances in X-ray fluorescence spectrometry and their applications

M West, AT Ellis, PJ Potts, C Streli, C Vanhoof… - Journal of Analytical …, 2015 - pubs.rsc.org
This review describes advances in the X-ray fluorescence (XRF) group of techniques
published approximately between April 2014 and March 2015 and is therefore restricted to a …

An X-ray fluorescence and machine learning based methodology for the direct non-destructive compositional analysis of (Th 1− x U x) O 2 fuel pellets

B Kanrar, K Sanyal, A Sarkar, RV Pai - Journal of Analytical Atomic …, 2023 - pubs.rsc.org
A highly sensitive analytical method for elemental quantification of U in (Th1− xUx) O2 mixed
oxide (MOX) fuel pellets is extremely necessary for nuclear fuel quality control. It will be an …

Porous organic polymer nanotubes as luminescent probe for highly selective and sensitive detection of Fe3+

M Wang, L Guo, D Cao - Science China Chemistry, 2017 - Springer
Two porous organic polymer nanotubes (PNT-2 and PNT-3) were synthesized via Ni-
catalyzed Yamamoto reaction, using 2, 4, 6-tris-(4-bromo-phenyl)-[1, 3, 5]-triazine (TBT) as …

Atomic spectrometry update—X-ray fluorescence spectrometry

M West, AT Ellis, PJ Potts, C Streli, C Vanhoof… - Journal of Analytical …, 2012 - pubs.rsc.org
This review demonstrates advances in XRF instrumentation, techniques and data
processing algorithms published during the last year. Pixellated detectors and EDXRF …

A green analytical approach for the direct non-destructive compositional analysis of (Th, U) O 2 fuel pellets by the X-Ray Fluorescence technique using single …

B Kanrar, K Sanyal, RV Pai - Journal of Analytical Atomic Spectrometry, 2022 - pubs.rsc.org
(Th, U) O2-based mixed oxide (MOX) fuel is the proposed fuel for advanced heavy water
reactors (AHWRs), which belong to the third stage of the three-stage Indian nuclear power …

Drastic improvement in detection limits in energy dispersive X-ray fluorescence geometry utilizing micro-focused bremsstrahlung excitation in thin-film sample …

K Sanyal, B Kanrar, S Dhara - Journal of Analytical Atomic …, 2021 - pubs.rsc.org
An excellent improvement in the detection limit is achieved using a lab-based micro-X-ray
fluorescence (micro-XRF) spectrometer equipped with a low-power X-ray tube that utilizes …

Trace element determinations in uranium by energy dispersive X-ray fluorescence spectrometry using thin film specimens

K Sanyal, NL Misra - Spectrochimica Acta Part B: Atomic Spectroscopy, 2019 - Elsevier
Thin film specimens on scotch tape base with analyte amounts in ng level have been used
for trace element determinations in Certified Reference Materials (CRMs) of uranium oxides …

Quantification and distribution of trace elements in fusion bead and pressed pellet specimens using a table top micro-X-ray fluorescence spectrometer

B Kanrar, K Sanyal, S Dhara - Spectrochimica Acta Part B: Atomic …, 2021 - Elsevier
Pressed pelletization and fusion bead methods are two very important sample preparation
techniques for X-Ray Fluorescence (XRF) analysis. Hence, along with the assessment of …

Energy dispersive X-ray fluorescence determination of uranium in different uranates using Rh Kα scattered peaks for matrix correction

SS Kumar, S Dhara - Spectrochimica Acta Part B: Atomic Spectroscopy, 2022 - Elsevier
Determination of uranium in different matrices and compounds is required for compositional
analysis and material characterization of uranium based materials. In the present work, we …

A highly precise micro-analytical XRF method for compositional characterization of fast breeder reactor fuels

K Sanyal, B Kanrar, SS Suresh, S Dhara - Journal of Analytical Atomic …, 2022 - pubs.rsc.org
Accurate and precise determination of plutonium and uranium in Fast Breeder Reactor
(FBR) fuels is one of the most important steps in the chemical quality control of these fuels …