Carbon-aware computing for datacenters

A Radovanović, R Koningstein… - … on Power Systems, 2022 - ieeexplore.ieee.org
The amount of CO emitted per kilowatt-hour on an electricity grid varies by time of day and
substantially varies by location due to the types of generation. Networked collections of …

A survey on power management techniques for oversubscription of multi-tenant data centers

S Malla, K Christensen - ACM Computing Surveys (CSUR), 2019 - dl.acm.org
Power management for data centers has been extensively studied in the past 10 years. Most
research has focused on owner-operated data centers with less focus on Multi-Tenant Data …

Carbon-aware electricity cost minimization for sustainable data centers

H Dou, Y Qi, W Wei, H Song - IEEE Transactions on …, 2017 - ieeexplore.ieee.org
In order to simultaneously power and cool hundreds of thousands of servers, large-scale
data centers usually consume several to tens of megawatts of electricity. This enormous …

Colocation data center demand response using Nash bargaining theory

Y Guo, H Li, M Pan - IEEE Transactions on Smart Grid, 2017 - ieeexplore.ieee.org
The huge yet flexible power consumption of data centers makes them promising resources
for demand response, particularly for emergency demand response (EDR) which requires a …

Paying to save: Reducing cost of colocation data center via rewards

MA Islam, H Mahmud, S Ren… - 2015 IEEE 21st …, 2015 - ieeexplore.ieee.org
Power-hungry data centers face an urgent pressure on reducing the energy cost. The
existing efforts, despite being numerous, have primarily centered around owner-operated …

Carbon Responder: Coordinating Demand Response for the Datacenter Fleet

J Xing, B Acun, A Sundarrajan, D Brooks… - arXiv preprint arXiv …, 2023 - arxiv.org
The increasing integration of renewable energy sources results in fluctuations in carbon
intensity throughout the day. To mitigate their carbon footprint, datacenters can implement …

Simplifying self-adaptive and power-aware computing with Nornir

D De Sensi, T De Matteis, M Danelutto - Future Generation Computer …, 2018 - Elsevier
Self-adaptation is an emerging requirement in parallel computing. It enables the dynamic
selection of resources toallocate to the application in order to meet performance and power …

Dynamic multi-tenant coordination for sustainable colocation data centers

Y Guo, M Pan, Y Gong, Y Fang - IEEE Transactions on Cloud …, 2017 - ieeexplore.ieee.org
Colocation data centers are an important type of data centers that have some unique
challenges in managing their energy consumption. Tenants in a colocation data center …

A carbon-aware incentive mechanism for greening colocation data centers

MA Islam, H Mahmud, S Ren… - IEEE Transactions on …, 2017 - ieeexplore.ieee.org
The massive energy consumption of data centers worldwide has resulted in a large carbon
footprint, raising serious concerns to sustainable IT initiatives and attracting a great amount …

[图书][B] A Survey on coordinated power management in multi-tenant data centers

TZ Oo, NH Tran, S Ren, CS Hong - 2018 - Springer
Electrical generation and distribution systems have remained essentially unchanged almost
for a century since their inception. The recent increase in fluctuating renewable energy …