Electric Transmission and Distribution Network Air Pollution

S De Vito, A Del Giudice, G Di Francia - Sensors, 2024 - mdpi.com
There is a consensus within the scientific community regarding the effects on the
environment, health, and climate of the use of renewable energy sources, which is …

Directions of development of diagnostic methods of vacuum medium-voltage switchgear

P Węgierek, D Kostyła, M Lech - Energies, 2023 - mdpi.com
The development of power grid infrastructure and increasingly stringent environmental
regulations have intensified work, carried out by researchers and electrical equipment …

[HTML][HTML] Detection of corona faults in switchgear by using 1D-CNN, LSTM, and 1D-CNN-LSTM methods

YAM Alsumaidaee, CT Yaw, SP Koh… - Sensors (Basel …, 2023 - ncbi.nlm.nih.gov
The damaging effects of corona faults have made them a major concern in metal-clad
switchgear, requiring extreme caution during operation. Corona faults are also the primary …

Detection of Corona Faults in Switchgear by Using 1D-CNN, LSTM, and 1D-CNN-LSTM Methods

YA Mohammed Alsumaidaee, CT Yaw, SP Koh… - Sensors, 2023 - mdpi.com
The damaging effects of corona faults have made them a major concern in metal-clad
switchgear, requiring extreme caution during operation. Corona faults are also the primary …

Fault detection for medium voltage switchgear using a deep learning Hybrid 1D-CNN-LSTM model

YAM Alsumaidaee, JKS Paw, CT Yaw, SK Tiong… - IEEE …, 2023 - ieeexplore.ieee.org
Medium voltage (MV) switchgear is a vital part of modern power systems, responsible for
regulating the flow of electrical power and ensuring the safety of equipment and personnel …

Detecting arcing faults in switchgear by using deep learning techniques

YA Mohammed Alsumaidaee, CT Yaw, SP Koh… - Applied Sciences, 2023 - mdpi.com
Switchgear and control gear are susceptible to arc problems that arise from slowly
developing defects such as partial discharge, arcing, and heating due to faulty connections …

[HTML][HTML] Monitoring in 6–35 kV power networks, location of single-phase ground fault and detection of fault feeder

V Kachesov, A Lebedev, E Kitova - … Journal of Electrical Power & Energy …, 2023 - Elsevier
To minimize the negative impact of arc overvoltage in three-phase electrical power system
(ES) with the ungrounded or high impedance grounded neutral, it is proposed to monitor …

Construction smart system for monitoring technical condition of furnace transformer vacuum circuit breaker

IR Abdulveleev, AS Karandaev… - 2023 International …, 2023 - ieeexplore.ieee.org
The introduction of systems for technical condition monitoring is relevant for high-voltage
vacuum circuit breakers (VCB) that switch furnace transformers. Among other parameters …

Audio General Recognition of Partial Discharge and Mechanical Defects in Switchgear Using a Smartphone

D Dai, Q Liao, Z Sang, Y You, R Qiao, H Yuan - Applied Sciences, 2023 - mdpi.com
Mechanical defects and partial discharge (PD) defects can appear in the indoor switchgear
of substations or distribution stations, making the switchgear a safety hazard. However …

[PDF][PDF] Abnormal Action Recognition with Lightweight Pose Estimation Network in Electric Power Training Scene

Y Cai, R Qin, J Tang, L Zhang, X Bi… - … , Materials and Continua, 2024 - cdn.techscience.cn
Electric power training is essential for ensuring the safety and reliability of the system. In this
study, we introduce a novel Abnormal Action Recognition (AAR) system that utilizes a …