[HTML][HTML] ICP-OES capabilities, developments, limitations, and any potential challengers?

J Olesik - 2020 - spectroscopyonline.com
Inductively coupled plasma–optical emission spectrometry (ICP-OES) has been one of the
most widely used atomic spectroscopy techniques for the last 40 years (1). This paper …

Atomic spectrometry update: review of advances in atomic spectrometry and related techniques

EH Evans, J Pisonero, CMM Smith… - Journal of Analytical …, 2016 - pubs.rsc.org
This review of 151 references covers developments in 'Atomic Spectrometry'published in the
twelve months from November 2014 to November 2015 inclusive. It covers atomic emission …

Spatially resolved measurements to improve analytical performance of solution-cathode glow discharge optical-emission spectrometry

AJ Schwartz, SJ Ray, GCY Chan, GM Hieftje - Spectrochimica Acta Part B …, 2016 - Elsevier
Past studies of the solution-cathode glow discharge (SCGD) revealed that elemental and
molecular emission are not spatially homogenous throughout the source, but rather conform …

Non-analyte signals and supervised learning to evaluate matrix effects and predict analyte recoveries in inductively coupled plasma optical emission spectrometry

JA Carter, JT Sloop, T Harville, BT Jones… - Journal of Analytical …, 2020 - pubs.rsc.org
A supervised data-driven methodology was used to evaluate matrix effect severity and the
consequent analytical signal bias caused by easily ionizable elements (EIEs) in inductively …

Effect of laser intensity on radio frequency emissions from laser induced breakdown of atmospheric air

L Vinoth Kumar, E Manikanta, C Leela… - Journal of Applied …, 2016 - pubs.aip.org
The studies on the effect of input laser intensity, through the variation of laser focusing
geometry, on radio frequency (RF) emissions, over 30–1000 MHz from nanosecond (ns) and …

Identifying and assessing matrix effect severity in inductively coupled plasma optical emission spectrometry using non-analyte signals and unsupervised learning

JA Carter, JT Sloop, T McSweeney, BT Jones… - Analytica Chimica …, 2019 - Elsevier
An unsupervised data-driven methodology is used to quantify matrix effects caused by
carbon and easily ionizable elements (EIEs) in inductively coupled plasma optical emission …

Evaluation of matrix effects in a pulsed electrolyte cathode atmospheric pressure discharge source for atomic emission

P Zheng, S Li, J Wang - Analytical Letters, 2018 - Taylor & Francis
In sample measurements, matrix effects are unavoidable. The matrix effects are one of the
main factors affecting the accuracy of the pulsed electrolyte cathode atmospheric pressure …

Jake A. Carter, John T. Sloop, Tina Harville, Bradley T. Jones and George L. Donati

T Harville - … THE GAP BETWEEN CHEMICAL ANALYSIS AND …, 2020 - search.proquest.com
The inductively coupled plasma (ICP) is a powerful and robust energy source for
vaporization, atomization, excitation and ionization in atomic spectrometry. 1-3 The strengths …

Jake A. Carter, John T. Sloop, Tina McSweeney, Bradley T. Jones and George L. Donati

L Donati - … THE GAP BETWEEN CHEMICAL ANALYSIS AND …, 2020 - search.proquest.com
Inductively coupled plasma optical emission spectrometry (ICP OES) is a wellestablished
and powerful analytical method for elemental analysis [1-3]. Given its position in atomic …

Análisis multilemental de minerales lateríticos pro ICP-OES. Efectos matriz, su reducción y posibles mecanismos

E Abad Peña - 2018 - digital.csic.es
Se desarrolló un procedimiento para la determinación de los elementos en baja
concentración Ca, Co, Cu, K, Na, P, V, Zn junto a los mayoritarios Al, Cr, Fe, Mg, Mn y Ni en …