Thermo-economic analysis and multi-objective optimization of vapour cascade refrigeration system using different refrigerant combinations: A comparative study

R Roy, BK Mandal - Journal of Thermal Analysis and Calorimetry, 2020 - Springer
A numerical investigation of energetic, exergetic, economic and environmental
performances of a 50-kW cooling capacity cascade refrigeration system using four different …

A Parametric Study on a Subcritical CO2/NH3 Cascade Refrigeration System for Low Temperature Applications

B Yilmaz, E Mancuhan… - Journal of Energy …, 2018 - asmedigitalcollection.asme.org
Adverse effects of synthetic refrigerants on the environment have led to replacing them with
natural refrigerants. The common candidates are ammonia, carbon dioxide, and several …

Comparative analysis of cascade refrigeration system based on energy and exergy using different refrigerant pairs

V Kumar - Journal of Thermal Engineering, 2020 - dergipark.org.tr
In this study a comparative analysis on the basis of energy and exergy of cascade
refrigeration system using different refrigerant pair, R13 for low temperature cycle (LTC) and …

Comparative 3E Analysis of Dual-Purpose Compression Refrigeration Systems Operating Under Various Climates in Multi-purpose Cold Storage Facilities

SA Zarabadi, M Mafi - Arabian Journal for Science and Engineering, 2024 - Springer
Due to the strong dependence of the food industry on the cold chain, utilizing an optimal
refrigeration facility plays a crucial role. This study focuses on the pattern of energy …

Etude de l'évaporation du CO2 dans des microcanaux intégrés dans des détecteurs en silicium: approches numérique et expérimentale

M Vacher - 2024 - theses.hal.science
En raison de ses bonnes propriétés thermo-physiques, et de son faible pouvoir de
réchauffement (GWP), pour certaines applications scientifiques, le CO2 est considéré …

Cascade refrigeration system with environment friendly refrigerants as R290 and ammonia

VN Raibhole, DA Kamble - International Journal of …, 2022 - inderscienceonline.com
Many industrial applications need low-temperature cooling which single-stage refrigeration
systems are unable to produce efficiently due to specific limitations of refrigerants used …

Effects of regenerator and refrigerant on performance of cascade refrigeration system

Z LIANG, J SHEN, S HAN - Food and Machinery, 2023 - ifoodmm.cn
In order to optimize the cascade refrigeration system, the thermodynamic models of cascade
refrigeration systems were established in this study, and the effects of low and high …

[PDF][PDF] USO DE LOS REFRIGERANTES NATURALES (CO2, NH3) EN SISTEMAS DE REFRIGERACIÓN INDUSTRIAL DE MEDIANO TAMAÑO

JAF Benítez, R Alonso - … en Ciencias y Técnicas del Frío …, 2024 - revistas.innovacionumh.es
En la última década el CO2 ha recibido un gran impulso en el ámbito de la refrigeración
comercial centralizada donde se muestra como alternativa a largo plazo de los sistemas …

A Theoretical Thermodynamic Analysis of R1234yf/CO2 Cascade Refrigeration System

A Ghosh, A Sharma, B Varshney, Chirag… - … Conference on Recent …, 2022 - Springer
The cascade refrigeration cycle is a multi-phase thermodynamic cycle that uses multiple
refrigeration cycles combined with a heat exchanger to enhance the refrigeration effect. It …

산업공정용히트펌프/MVR 연계시스템의최적중간온도에대한사이클분석

김학수, 정유준, 정융, 문선영, 송찬호, 이공훈… - 설비공학논문집, 2024 - dbpia.co.kr
In this paper, a cycle analysis was performed on a heat pump and MVR coupled system.
Through a cycle analysis, the integrated COP of a heat pump/MVR coupled system was …