Anniversary Paper: Development of x‐ray computed tomography: The role of Medical Physics and AAPM from the 1970s to present

X Pan, J Siewerdsen, PJ La Riviere… - Medical …, 2008 - Wiley Online Library
The AAPM, through its members, meetings, and its flagship journal Medical Physics, has
played an important role in the development and growth of x‐ray tomography in the last 50 …

Self‐calibration of a cone‐beam micro‐CT system

V Patel, RN Chityala, KR Hoffmann, CN Ionita… - Medical …, 2009 - Wiley Online Library
Use of cone‐beam computed tomography (CBCT) is becoming more frequent. For proper
reconstruction, the geometry of the CBCT systems must be known. While the system can be …

A prototype table‐top inverse‐geometry volumetric CT system

TG Schmidt, J Star‐Lack, NR Bennett… - Medical …, 2006 - Wiley Online Library
A table‐top volumetric CT system has been implemented that is able to image a 5‐cm‐thick
volume in one circular scan with no cone‐beam artifacts. The prototype inverse‐geometry …

Multisource inverse‐geometry CT. Part I. System concept and development

B De Man, J Uribe, J Baek, D Harrison, Z Yin… - Medical …, 2016 - Wiley Online Library
Purpose: This paper presents an overview of multisource inverse‐geometry computed
tomography (IGCT) as well as the development of a gantry‐based research prototype …

[PDF][PDF] Foxels for high flux, high resolution computed tomography (FoxelCT) using broad x-ray focal spots: theory and two-dimensional fan beam examples

G Alvare, R Gordon - Radiology and Diagnostic Imaging, 2017 - researchgate.net
Purpose: In general, there is a reciprocal relationship between the width and flux from an x-
ray focal spot (corresponding to spatial resolution and photon noise), so that large focal …

Direct two‐dimensional reconstruction algorithm for an inverse‐geometry CT system

J Baek, NJ Pelc - Medical physics, 2009 - Wiley Online Library
An inverse‐geometry computed tomography (IGCT) system uses a large source array
opposite a smaller detector array. A previously described IGCT reconstruction algorithm …

Fourier rebinning algorithm for inverse geometry CT

SR Mazin, NJ Pelc - Medical physics, 2008 - Wiley Online Library
Inverse geometry computed tomography (IGCT) is a new type of volumetric CT geometry that
employs a large array of x‐ray sources opposite a smaller detector array. Volumetric …

Four-dimensional inverse-geometry computed tomography: a preliminary study

KH Kim, DS Shin, SW Kang, SH Kang… - Physics in Medicine …, 2021 - iopscience.iop.org
This study introduces and evaluates respiratory-correlated four-dimensional (4D) inverse
geometry computed tomography (IGCT). The projection data of the IGCT were acquired in a …

Single-view geometric calibration for C-arm inverse geometry CT

JM Slagowski, DAP Dunkerley, CR Hatt… - Journal of Medical …, 2017 - spiedigitallibrary.org
Accurate and artifact-free reconstruction of tomographic images requires precise knowledge
of the imaging system geometry. A projection matrix-based calibration method to enable C …

[HTML][HTML] Feasibility of CT-based 3D anatomic mapping with a scanning-beam digital x-ray (SBDX) system

JM Slagowski, MT Tomkowiak… - Proceedings of SPIE …, 2015 - ncbi.nlm.nih.gov
This study investigates the feasibility of obtaining CT-derived 3D surfaces from data
provided by the scanning-beam digital x-ray (SBDX) system. Simulated SBDX short-scan …