Cardiac MRI at low field strengths

AE Campbell‐Washburn, J Varghese… - Journal of Magnetic …, 2024 - Wiley Online Library
Cardiac MR imaging is well established for assessment of cardiovascular structure and
function, myocardial scar, quantitative flow, parametric mapping, and myocardial perfusion …

Low‐field MRI: a report on the 2022 ISMRM workshop

AE Campbell‐Washburn, KE Keenan… - Magnetic resonance …, 2023 - Wiley Online Library
In March 2022, the first ISMRM Workshop on Low‐Field MRI was held virtually. The goals of
this workshop were to discuss recent low field MRI technology including hardware and …

Low-cost high-performance MRI

M Sarracanie, CD LaPierre, N Salameh… - Scientific reports, 2015 - nature.com
Abstract Magnetic Resonance Imaging (MRI) is unparalleled in its ability to visualize
anatomical structure and function non-invasively with high spatial and temporal resolution …

Magnetic resonance fingerprinting using echo‐planar imaging: Joint quantification of T1 and relaxation times

B Rieger, F Zimmer, J Zapp… - Magnetic resonance …, 2017 - Wiley Online Library
Purpose To develop an implementation of the magnetic resonance fingerprinting (MRF)
paradigm for quantitative imaging using echo‐planar imaging (EPI) for simultaneous …

Fast quantitative low-field magnetic resonance imaging with OPTIMUM—optimized magnetic resonance fingerprinting using a stationary steady-state cartesian …

M Sarracanie - Investigative radiology, 2022 - journals.lww.com
Objective The aim of the proposed work is to develop model-based, fast multiparametric
magnetic resonance imaging (MRI) in field regimes where signal-to-noise ratio is poor, such …

Feasibility of MR fingerprinting using a high-performance 0.55 T MRI system

AE Campbell-Washburn, Y Jiang, G Körzdörfer… - Magnetic resonance …, 2021 - Elsevier
Background MR fingerprinting (MRF) is a versatile method for rapid multi-parametric
quantification. The application of MRF for lower MRI field could enable multi-contrast …

3D magnetic resonance fingerprinting on a low-field 50 mT point-of-care system prototype: Evaluation of muscle and lipid relaxation time mapping and comparison …

T O'Reilly, P Börnert, H Liu, A Webb… - … Resonance Materials in …, 2023 - Springer
Objective To implement magnetic resonance fingerprinting (MRF) on a permanent magnet
50 mT low-field system deployable as a future point-of-care (POC) unit and explore the …

Relaxation measurements of an MRI system phantom at low magnetic field strengths

MN Martin, KV Jordanova, AB Kos, SE Russek… - … Resonance Materials in …, 2023 - Springer
Objective Temperature controlled T1 and T2 relaxation times are measured on NiCl2 and
MnCl2 solutions from the ISMRM/NIST system phantom at low magnetic field strengths of 6.5 …

Multi-shot Echo Planar Imaging for accelerated Cartesian MR Fingerprinting: an alternative to conventional spiral MR Fingerprinting

AJV Benjamin, PA Gómez, M Golbabaee… - Magnetic resonance …, 2019 - Elsevier
Purpose To develop an accelerated Cartesian MRF implementation using a multi-shot EPI
sequence for rapid simultaneous quantification of T1 and T2 parameters. Methods The …

[PDF][PDF] Webb,., & Koolstra

T O'Reill, P Börnert, H Liu - 2023 - scholarlypublications …
Objective To implement magnetic resonance fingerprinting (MRF) on a permanent magnet
50 mT low-field system deployable as a future point-of-care (POC) unit and explore the …