A review of recent advances in tribology

Y Meng, J Xu, Z Jin, B Prakash, Y Hu - Friction, 2020 - Springer
The reach of tribology has expanded in diverse fields and tribology related research
activities have seen immense growth during the last decade. This review takes stock of the …

Management of periprosthetic bone cysts after total ankle arthroplasty

ES Hur, N Mehta, S Lee, DD Bohl - Orthopedic Clinics, 2023 - orthopedic.theclinics.com
The exact cause of bone cyst formation is likely multifactorial with contributing factors
including polyethylene wear, implant micromotion, and implant design. Nonoperative …

Mechanical micromodeling of stress-shielding at the bone-implant interphase under shear loading

Y Hériveaux, S Le Cann, M Fraulob, E Vennat… - Medical & Biological …, 2022 - Springer
Inserting a titanium implant in the bone tissue may modify its physiological loading and
therefore cause bone resorption, via a phenomenon called stress-shielding. The local stress …

Biomechanical analysis of three popular tibial designs for TAR with different implant-bone interfacial conditions and bone qualities: a finite element study

S Mondal, R Ghosh - Medical Engineering & Physics, 2022 - Elsevier
Background The long-term success of total ankle replacement (TAR) depends on both bone
ingrowth and remodelling. The extreme values of implant-bone micromotion hinder bone …

Expandable pedicle screw may have better fixation than normal pedicle screw: preclinical investigation on instrumented L4-L5 vertebrae based on various …

D Sanjay, JS Bhardwaj, N Kumar, S Chanda - Medical & Biological …, 2022 - Springer
Lumbar spine fracture is typically treated by means of screw fixation, the primary aim of
which is to reduce fracture by achieving bony union such that the spinal anatomy is restored …

Finite element stress analysis of the bearing component and bone resected surfaces for total ankle replacement with different implant material combinations

J Yu, D Zhao, WM Chen, P Chu, S Wang… - BMC Musculoskeletal …, 2022 - Springer
Background A proper combination of implant materials for Total Ankle Replacement (TAR)
may reduce stress at the bearing component and the resected surfaces of the tibia and talus …

Malalignment of the total ankle replacement increases peak contact stresses on the bone-implant interface: a finite element analysis

SWG van Hoogstraten, J Hermus, ACY Loenen… - BMC Musculoskeletal …, 2022 - Springer
Abstract Introduction Malalignment of the Total Ankle Replacement (TAR) has often been
postulated as the main reason for the high incidence of TAR failure. As the ankle joint has a …

The evaluation of artificial talus implant on ankle joint contact characteristics: a finite element study based on four subjects

T Liu, N Jomha, S Adeeb, M El-Rich… - Medical & Biological …, 2022 - Springer
Customized talus implants have been regarded as a better treatment alternative to talus
avascular necrosis than traditional surgical fusion because of its ability to maintain joint …

Finite-element analysis of the influence of tibial implant fixation design of total ankle replacement on bone–implant interfacial biomechanical performance

J Yu, C Zhang, WM Chen, D Zhao… - Journal of …, 2020 - journals.sagepub.com
Purpose: Implant loosening in tibia after primary total ankle replacement (TAR) is one of the
common postoperative problems in TAR. Innovations in implant structure design may ideally …

[HTML][HTML] A computational analysis of a novel therapeutic approach combining an advanced medicinal therapeutic device and a fracture fixation assembly for the …

S Mondal, DB MacManus, AF Bonatti… - Medical Engineering & …, 2023 - Elsevier
The occurrence of periprosthetic femoral fractures (PFF) has increased in people with
osteoporosis due to decreased bone density, poor bone quality, and stress shielding from …